What to do when ...

Problem

Various menu items cannot be called (shown
in gray) or the menus for the EPG and teletext
modes of operation cannot be called

Timer recording, Change timer and Clear timer
are not shown in the Video menu

”Connections” cannot be called in the Video
menu (shown in gray)

The ”Stations” item in the TV menu and the
”Automatic station search” item in the main
information cannot be called

Control of the Loewe VCR with the video control
bar and the timer does not work or does not
work properly

General problems with connecting external
devices through an AV input

Picture shifted horizontally

Possible cause

”Simplifi ed control” activated in main information

No video recorder logged in

a) A timer recording is currently in progress

b) You are recording from the TV set with the

video bar

The child lock is activated. If these menus were
accessible, children could still set the programs.

a) The VCR’s Digital Link function is not activated

or not possible

b) Euro-AV cable not connected
c) Video recorder not logged in

a) The device is not logged in in the ”Connec-

tions” menu or is connected differently to
shown in the connection diagram

b) The AV norm is set incorrectly
c) The AV signal is set incorrectly

The TV set is in the Southern hemisphere (e.g.
Australia, South Africa)

Remedy

Deactivate ”Simplifi ed control” in the main
information. Press the INFO-button, select ”Select
control level” and call with OK. Set the ”Simplifi ed
control” to ”no”.

Log in VCR in the TV menu – Connections.

a) Wait until the timer recording has ended or

clear the timer.

b) Wait until you stop recording.

Deactivate program-related child lock: Switch off
child lock or enter PIN in the TV menu - Settings.

a) Activate Digital Link in the VCR (see operating

instructions of the VCR)

b) Connect the Euro-AV cable
c) Log in the VCR

a) Compare the connection diagram with the

actual installation in the ”Main information”
under ”Connections” and connect as shown if
necessary.

b) Set the correct norm.
c) Set the correct AV signal.
If ”Automatic” is set for AV norm or AV signal,
this can lead to wrong detection in the case of
non-standardized signals. In this case the norm
and signal must be set according to the operating
instructions of the external device.

Set the horizontal position:
1. Call the main information with INFO
2. Call Index – Set picture – Horizontal displace-

ment

3. Set horizontal picture position.