Ic series, Lens, 2s va 6u – Lightolier IC Series User Manual

Page 2: Options/accessories, Specifications, Specifications (continued), Ordering information, Page 2 of 2, Job information type

Advertising
background image

Lens

IC Series

Page 2 of 2

2' x 2' Recessed Fluorescent, IC Lens Frame Troffer

Static, 2-6" U Lamp T8

IC

Standard IC Lens

IY

For NYC Code – I.B.E.W. Manufactured

0.0

45.0

90.0

FLUX

0

1708

1708

1708

5

1700

1698

1702

162

15

1620

1635

1655

462

25

1467

1501

1531

691

35

1231

1274

1328

798

45

904

959

1069

748

55

553

592

651

531

65

313

269

331

302

75

173

141

207

180

85

59

54

68

63

90

0

0

0

Model No. ICS2GFSVA26U120SO

LER = FP - 58.4

IW - 56.5

BF - 0.87

Comparative yearly lighting energy cost per

1000 lumens = $3.86

Report Number: G00036
Catalog Number: ICS2GFSVA26U120SO
Lamp: (2) T8 U6
Luminaire: IC 2' X 2' with VA lens
Ballast: M2-RN-T81LL-D-120
Report is based on 2750 Lumens per lamp.
Efficiency: 71.6%
CIE Type-Direct-Indirect
Plane:

0-Deg

90-Deg

Spacing Criteria:

1.2

1.2

Shielding Angles:

90

90

Plane:

0-Deg

90-Deg

Luminous Length:

21.720

21.720

CANDELA DISTRIBUTION

AVERAGE AVERAGE AVERAGE AVERAGE

IN DEG.

0-DEG.

45-DEG.

90-DEG.

45

4199.

4454.

4565.

55

3167.

3390.

3728.

65

2432.

2091.

2572.

75

2195.

1789.

2627.

85

2223.

2035.

2563.

LUMINANCE DATA IN CANDELA/SQ. METER

ZONE

LUMENS % LAMP

% FIXT

0

0-

0

30

1315

23.9

33.4

0

0-

0

40

2113

38.4

53.7

0

0-

0

60

3392

61.7

86.1

0

0-

0

90

3938

71.6

100.0

90-180

000

0

0.0

00

0.0

0

0-180

3938

71.6

100.0

ZONAL LUMEN SUMMARY

Mounting Height

Lengthwise

Crosswise

Room

Luminaires

Luminaires

Size

0 Deg Plane

90 Deg Plane

8.5 10 13 16

8.5 10 13 16

30x30

50 54 58 63

47 51 55 60

40x40

47 50 53 56

44 47 50 53

60x30

52 56 60 64

51 55 58 62

60x60

44 46 47 50

41 43 44 48

100x100

44 44 43 45

42 41 40 41

TYPICAL V.C.P.'s

Options/Accessories

Special Lenses: Substitute VY for VA (standard) = .125" nominal pattern 12 with 7.8 oz. average weight per
square foot. Substitute VI for VA (standard) = .125" nominal pattern 12 with 6.8 oz. average weight per
square foot.
Radio Interference Filter: To order one RIF per fixture; SUFFIX: R.

To order one RIF per ballast; SUFFIX: B.

Electrical Wiring Options: Consult factory.
Drywall Kit: Order Catalog Number: FK92X2. (Request Folio OA30-10 Rev. A).
Chicago Plenum: SUFFIX: C.

Specifications

Performance: In an installation of 2 lamp 31W luminaires in a room cavity ratio of 1, reflectance
80% ceiling, 50% wall, 20% floor, the C.U. shall not be less than .76. To prevent glare the VCP shall
be not less than 41 either lengthwise or crosswise (at 100fc level) and the average brightness at 65°
shall not exceed 2572 candelas per square meter. To control veiling reflections, luminaire output in
the 30°-90° zone shall not be less than 66.9%.
Materials: Chassis parts are die-formed code gauge cold rolled steel. Housing with side rails hemmed
over and housing ends turned-in for safe handling.

Specifications (continued)

Finish: Chassis exterior–black baked polyester enamel. Cavity–white baked polyester enamel
minimum 86% reflectance. Rust preventative undercoating.
Lenses: VA (standard) extruded virgin acrylic, 3/16" square based female cones, running 45° to the
panel edge, .095" nominal thickness (similar to pattern 12). VY (optional) .125" nominal pattern 12
with 7.8 oz. average weight per square foot. VI (optional) .125" nominal pattern 12 with 6.8 oz. aver-
age weight per square foot.
Electrical: Thermally protected class “P” ballast C.B.M. approved, non PCB. If K.O. is within 3" of
ballast, use wire suitable for at least 90°.
Labels: I.B.E.W. UL and ULc Listed.
This product may have a mercury containing lamp. Manage in accord with Disposal Laws. See:
www.lamprecycle.org

COEFFICIENTS OF UTILIZATION –

ZONAL CAVITY METHOD. EFFECTIVE
FLOOR CAVITY REFLECTANCE 0.20

0

RC

80

50

30

RW 70 50 30 50 30 10 50 30 10

1

79 76 73 71 69 67 68 66 65

2

72 67 62 63 60 57 61 58 55

3

66 60 54 56 52 49 54 51 48

4

61 53 48 51 46 42 49 45 42

5

57 48 42 46 41 37 44 40 37

6

53 44 38 42 37 33 41 36 33

7

49 40 34 38 33 29 37 33 29

8

46 36 31 35 30 26 34 30 26

9

43 34 28 32 27 24 32 27 24

10 40 31 26 30 25 22 29 25 22

IC Series:

Recessed Lens

suitable for

Direct Thermal

Insulation

Contact

Body Style:

S=Static

Fixture

Width

Lens Shielding

Type:

VA=Virgin acrylic (standard),

see options and
consult factory

Voltage:

120, 277 or

UNV=120-277

Ceiling Type:

G= Grid

(lay-in T bar)

T= Slot grid

Lens Frame:

FS= Flat steel frame.
RA=Regressed

aluminum
frame.

FA= Flat aluminum

frame.

Lamp Type/

Fixture Length:

(By Others)

6U=6"U Lamp T8

(Nominal 24")

Lamp

Quantity

2=2 lamps

Ballast Type:

<20THD <10THD

1-2 Lamp Elec. T8

SO *

H

I *

*Instant Start Standard

NOTE:
For T8 UNV, you must use H

I Ballast Code.

2

S

VA

6U

Options:

Lamps
Flex
EM Pack
Fuse

(Consult your

representative)

Ordering Information

Explanation of Catalog Number. Example: ICS2GFSVA26UUNVHI

-

Job Information

Type:

For Factory Technical Information: (978) 657-7600 • Fax (978) 658-0595

08/10

631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
www.lightolier.com © Philips Group

Section 7/Folio Q80-10 Rev. A

Advertising