ELEVATION POTENTIOMETER CALIBRATION

Enter Diagnostic Mode:
2. Power up treadmill in Diagnostic Mode:
Sprint – Press DISPLAY & START simultaneously.
SST & PRG – Press MANUAL & START simultaneously.

Calibrate the elevation potentiometer:
1. Visually confirm treadmill is level. (0% grade)
2. The potentiometer should read between –0.6 and -0.1

in the selectable display

window.

3. If the setting is incorrect, follow the steps below.

STEP 1:

Turn the post of the potentiometer all the way
CLOCKWISE.

STEP 2:

Slowly turn the potentiometer COUNTER-CLOCKWISE
until the setting is correct.

4.

Carefully install potentiometer into the motor housing.
*NOTE: The setting may vary when inserting the potentiometer into
the motor. As long as the change is minimal, fine adjustment can be
achieved after the potentiometer is secured in motor housing.

5.

Press OFF to turn treadmill off.

P/N #70088 110volt

P/N #70126 220volt

P/N #71013

NOTE: ELONGATED BRACKET HOLES ARE FOR

POTENTIOMETER FINE ADJUSTMENT.