Is: c3mr – Lightolier IS:C3MR User Manual

Page 2

Advertising
background image

READ AND UNDERSTAND THESE INSTRUCTIONS BEFORE INSTALLING LUMINAIRE

This luminaire is intended for installation in accordance with the National Electrical Code and local regulations.

To assure full compliance with local codes and regulations, check with your local electrical inspector before

installation. To prevent electric shock, turn off electricity at fuse box before proceeding.

Retain these instructions for maintenance reference.

INSTRUCTION SHEET NO.

IS: C3MR

B0206

Page 2 of 2

A

COMPANY

631 Airport Road, Fall River, MA 02720

INSTALLATION PROCEDURE FOR CALCULITE

® EVOLUTION TRIMS

8. Install TRIM FACEPLATE by compressing TORSION SPRING
into corresponding detail of TRIM BODY then pushing TRIM
FACEPLATE up flush to ceiling.

Fig’s 4 & 5


TRIM MAINTENANCE
RELAMPING - Make sure that power to luminaire is OFF.
To relamp, simply swing TRIM FACEPLATE down allowing
TORSION SPRING to hold in place. Pull down on LAMP
REMOVAL SPRING. Disconnect LAMP from LAMP
SPRINGS and SOCKET. Install new LAMP following steps
4, 5, and 6 above.

CARE OF ALZAK REFLECTOR- Wipe with a soft, clean,
dry, lint-free cloth, or wipe with a soft clean cloth
dampened in mild detergent solution, then rinse and
dry with a lint-free soft cloth.

Fig. 1

Fig. 2

Securing Clips in
the disengaged
position

Fig. 3

Insert Trim Body

Engage Clip

Trim Body Flush or
slightly recessed

Fig. 4

Fig. 5

Advertising