Attaching conduit, Making the connection – Lathem ATDDC4 User Manual

Page 8

Advertising
background image

ATDDC4 Series Installation & User’s Guide

Page 6

Attaching Conduit


The Electrical Supply can be brought into the ATDDC4 enclosure from

any of the top three vent-hole positions, from the back, or from either
side. Conduit access is not available from the bottom.

Note: Optional plastic end-panels may be ordered (left VIS1551-L),
(right VIS1551-R) that have access holes pre-drilled to allow side

access.
If Conduit access is through either of the optional plastic end-

panels, Conduit should NOT be used to support the weight of the
Clock. The Clock must be properly secured to a wall.


Remove the vent cap from the selected mounting hole (if not accessing

through side panels). Attach the conduit with locking nut and extend
the wires into the enclosure.

Making the Connection

1. Slide the circuit board with display part-way back into the case.

Connect the two black wires from the circuit board to the power-

wires from the power cord or conduit using wire nuts. Connect the
Ground Wires from the circuit board and from the power source

(usually green) to the green ground screw on the inside of he
enclosure.


2. Slide the circuit board fully into place, then slide the front lens

into place. Note: the inside of the lens has a paper backing

which should not be removed. The end with wider paper should
go to the right
.
Replace the end caps and secure with the two

Phillips head screws.

3. When the clock is energized, it will set itself, upon receiving the

AirTime radio signal.

ATDDC4 Series Installation & User’s Guide

Page 7

Double Mount – Wall

The ATDDC4 SERIES requires optional mounting kit (SAM0625)

Tools required for mounting the clock:

• Flat blade screwdriver
• Phillips head screwdriver

• 15/16" open end wrench

The double wall mount plate attaches to a double or single gang box
installed securely in the wall. Required wiring should be available

through the gang box at time of installation.

Installation Steps


1. Remove the two chase nipples from the mounting plate posts.

2. Secure the mounting plate securely to the gang box with the proper

screws. (not supplied)

Note: The long dimension of the mounting plate must be perpendicular
to the ground to assure proper alignment of wall clocks.


See remaining Wall or Ceiling mount instructions below

Double-Mounting - Wall
1. Place the two clock enclosures back to back and secure by inserting

a #10 screw through the four mounting holes using lock washers
and nuts supplied with the mounting kit.

2. Attach the modified end cap to the clock’s end to be attached to

the wall mount plate using the original end cap screws.

3. Align the holes of end cap support plate with the holes in the

modified end cap and secure with 4 #6 Phillips head screws

(supplied).

4. Line the two posts from the mounting plate up with the two holes

of the modified end cap. Insert the chase nipples through the holes
of the modified end cap and secure to the mounting plate with a

15/16" wrench.

Advertising