10 stove installation, Bypass handle installation, Rear vent configuration – Lopi Leyden Wood Stove User Manual

Page 10

Advertising
background image

10

Stove Installation

(for qualified installers only)

© Travis Industries

100-01177

4060802

Bypass Handle Installation

See Figure 4 for details on installing the bypass handle.

Line up the set screws on the bypass handle

with the dimples on the bypass shaft. Tighten

with the included 1/8” hex wrench.

1/8" Hex

Figure 4

Rear Vent Configuration

The rear vent configuration is only for masonry fireplace installations (hearth stove). All steel chimney
applications require the top vent configuration.

The vent (chimney connector) may be directed to the rear of the appliance when installed into a masonry
fireplace. See Figure 5 for details.

The flue collar is held in place with three bolts

and two nuts. Use two 7/16" open-end

wrenches to remove the bolts and nuts.

7/16" Wrench

NOTE: Make sure the gasket

underneath the flue collar is properly

located and seals the flue collar when

it is installed.

Open the bypass - this

allows for access to the

nut under the flue collar.

Remove the flue collar and rotate it to the rear.

Use the existing bolts and nuts to attach the

sides of the flue. For the center connection

use the bolt and acorn nut included in the

owner's pack.

Figure 5