2.

Press and hold the SET key for about 2 seconds. The temperature digit will
start flashing. Press the + or MIN/MAX key to set the high outdoor temp alarm
value. (Keep holding the key will allow the value to increase faster.)

3. Press

the

ALARM key to confirm the setting. The digit will stop flashing. Press

the SET key to switch on or off the alarm. (The showing of the icon (((

y)))

means that the alarm is switched on.)

4. Press

the

ALARM key once. The Low Outdoor Temperature alarm display will

be shown.

5.

Press and hold the SET key for about 2 seconds. The temperature digit will
start flashing. Press the + or MIN/MAX key to set the low outdoor temp alarm
value. (Keep holding the key will allow the value to increase faster.)

6. Press

the

ALARM key to confirm the setting. The digit will stop flashing. Press

the SET key to switch on or off the alarm. (The showing of the icon (((

y)))

means that the alarm is switched on.)

7. Press

the

HISTORY key or wait for about 30 seconds and the display will

return to normal display mode automatically.


In case the temperature value meets the condition for high alarm or low alarm, the
value will be blinking, along with the corresponding icon ("HI AL"/ "LO AL").
And the buzzer will ring for 2 minutes. User then may press any key to stop the ring.
User may quit the alarm setting and return to the normal display mode by pressing the
HISTORY key.