Changing the motor – Lathem 2000 User Manual

Page 14

Advertising
background image

Mechanical Time Recorder User’s Guide

Page 13

Changing the Motor

Figure 10

1. Unplug cord from wall outlet (except 2100BATT).

2. Remove type section from main frame (see “Replacing

the Type Section”).

3. Figure 10 shows a close-up of cam block terminal.

4. Disconnect Motor Wire Leads – 10.1 by turning each

Screw – 10.2 one-quarter of a turn counterclockwise.

5. Remove the Motor Clutch – 10.3 from its shaft. The

shaft has LEFT HAND threads – remove clutch by
turning clockwise.

6. Hold Motor Bracket – 10.4 and loosen Motor Mounting

Screws – 10.5. Remove and retain screws and bracket
from old motor.

7. Install motor clutch on new motor. Turn counterclockwise

to tighten. DO NOT OVERTIGHTEN OR BEND – YOU
MAY DAMAGE INTERNAL MOTOR GEARS.

8. Install new motor.

9. Plug cord back in wall outlet, and reset the time.

Advertising