Installation, Troubleshooting, Weee , recycling of electronic products – Lindy 25044 User Manual

Page 2: Radio frequency energy, certifications

Advertising
background image

Installation

Operating Environment

This switch must be installed and operated within the limits

of the specified operating temperature and humidity (see the

Specifications section)

Do not place objects on top of the unit. Do not obstruct any

vents on the unit

Do not position the switch in direct exposure to the sun, or

near any heat source such as a heater, radiator etc.

Prevent water and moisture entering the unit. If necessary,

use a dehumidifier to reduce humidity.

Connecting Network Devices

1. This switch features Auto MDI/MDI-X RJ45 ports for easy

connection to other network devices using straight-through

type network patch cable, cross over cables are not

required.

2. The network patch cables must comply with the Category 5

standard or higher for 10 and 100Mbps data transmission,

and at least Category 5e for 1000Mbps transmission.

3. Please be aware that the maximum length of any Ethernet

segment is 100m. If you are connecting the switch to a

patch panel, a maximum 5m of cable should be used to

connect the switch to the panel; similarly any equipment

connected to the switch should also use a maximum of 5m

cable, per device. Installation cabling may use the

remaining length. Using higher specification network cable

may increase this to a certain extent.

4. Connect the power adapter to the mains and to the power

socket on the switch.

Troubleshooting

The power LED is not lit

Check the power adapter is properly connected to both the

mains outlet and the switch and that the power at the mains

socket is switched on!

The 1000M Link LED is not lit when connected to a

1000Mbps device

Check the network cable. Make sure it is properly

connected to the switch and to the network device. The

segment length must be below 100 metres (see remark in

Installation) and all cables and connectors in between must

be at least category 5e compliant. We recommend the use

of professionally manufactured cables with this product to

ensure full Gigabit compatibility (Cables which are self-

made may be non-compliant with Gigabit specifications

and requirements!)

Should problems persist connect a local 1000Base-T device

to check that the port is working correctly. If this works

correctly it is probable that the network segment you want to

use contains equipment which is not 1000Base-T compliant.

Check the network segment and replace non-complaint

equipment with higher specification cables and connectors

where required.

If you experience any other problems with the switch please

contact your supplier or LINDY.

WEEE , Recycling of Electronic Products

Europe

In 2006 the European Union introduced

regulations (WEEE) for the collection and

recycling of all waste electrical and electronic

equipment. It is no longer allowable to simply

throw away electrical and electronic equipment.

Instead, these products must enter the recycling process.

Each individual EU member state has implemented the WEEE

regulations into national law in slightly different ways. Please

follow your national law when you want to dispose of any

electrical or electronic products. More details can be obtained

from your national WEEE recycling agency.

Germany / Deutschland

Die Europäische Union hat mit der WEEE Direktive umfassende

Regelungen für die Verschrottung und das Recycling von

Elektro- und Elektronikprodukten geschaffen. Diese wurden von

der Bundesregierung im Elektro- und Elektronikgerätegesetz –

ElektroG in deutsches Recht umgesetzt. Dieses Gesetz

verbietet vom 24.März 2006 an das Entsorgen von Elektro- und

Elektronikgeräten über die Hausmülltonne! Diese Geräte

müssen den lokalen Sammelsystemen bzw. örtlichen

Sammelstellen zugeführt werden! Dort werden sie kostenlos

entgegen genommen. Die Kosten für den weiteren

Recyclingprozess übernimmt die Gesamtheit der

Gerätehersteller.

Radio Frequency Energy, Certifications

FCC Warning

This Equipment has been tested and found to comply with the

limits for a Class A digital device, pursuant to part 15 of the FCC

Rules. These limits are designed to provide reasonable

protection against harmful interference when the equipment is

operated in a commercial environment. This equipment

generates, uses, and can radiate radio frequency energy and, if

not installed and used in accordance with the instruction manual,

may cause harmful interference to radio communications.

Operation of this equipment in a residential area is likely to

cause harmful interference in which case the user will be

required to correct the interference at his own expense.

This device complies with Part 15 of the FCC Rules. Operation

is subject to the following two conditions:

(1) this device may not cause harmful interference, and

(2) this device must accept any interference received; including

interference that may cause undesired operation.

LINDY No. 25044

1

st

Edition NOV 2007

For Commercial Use only!

Tested to Comply with FCC Standards

www.lindy.com