NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.

c

himney

r

equiremenTs

The L

egacy

™/e

Lite

™ c/e260 inserts are approved for use in

masonry fireplaces built to UBC Chapter 37 or equivalent

with a minimum 30” opening at the front of the fireplace.

Do not remove brick or mortar from masonry fireplace to

accommodate insert. Do not remove brick or mortar from
masonry fireplace to accommodate insert. Approved with or
without positive flue connection. Approved with minimum
6” (152mm) diameter stainless steel listed reline system.
Ask your dealer for recommended chimney size. Country
Collection inserts are tested to UL 1482 / ULC S628 and
listed by OMNI-Test Laboratories, Inc.; Beaverton, OR.

Remove and clean behind unit frequently, as creosote build

up may occur rapidly.

i

nsTallaTion

P

roceDures

- m

asonry

c

himney

NOTE: Although not required, a full-length stainless steel liner is

recommended for optimum safety and performance. See your

Lennox Hearth Products dealer for details.

NOTE: When installing your stove with a positive flue connection,

be sure to leave the insulation off the surround panels (flanges) and

leave a 1/4” (6mm) airspace insulation off the surround panels

and the facing of your fireplace.

1. READ ENTIRE INSTALLATION INSTRUCTIONS.

2. Check all REQUIRED CLEARANCES as specified in the previous

section (Page 7) of this installation instruction booklet.

3. Wear gloves during installation in case of sharp edges on the

stove and it’s parts

4. Determine the depth of the fireplace lintel. The lintel is the

masonry area over the fireplace opening, and is supported by

a noncombustible plate, usually of steel. The depth may vary

from a single brick width (4”/102mm) to that of several brick.

If any portion of the flue collar opening on top of the insert (as

shown in the diagram below) will project under the lintel area,

a deflector plate must be mechanically attached to the fireplace

insert to divert heat and gases away from the lintel. Consult your

dealer for the correct attachment piece. Compare lintel depth

to the distance from the flue collar opening to the fireplace to

determine if this caution pertains to your installation. If there

is sufficient clearance, a flue offset may also be used. Consult

your dealer.

5. Open or remove the existing fireplace damper. Make sure the

damper cannot fall closed.

6. Install the two 1/2” x 3” (13mm x 76mm) leveling bolts -heads

up- a few turns in the leveling nuts on each side of the outer

chamber of the insert at the lower rear corners.

7. Position the insert in the center of the fireplace opening and

push it back until the surround brackets are approximately 2”

(51mm) away from the fireplace front.

8. Install the side surround panels and push the insert up snug

against the fireplace face. Then with the location selected re-

move the surround panels and level the stove with the leveling

bolts using a 3/4” (19mm) socket, extensions (to reach the bolt

head), and a ratchet.

9. Glue the insulation around the outer edge of both the top and

side surround panels.

10. Install the surround panels loosely, align and tighten. Check

for a tight fit against the fireplace.

11. Locate the draft rod extension (5/16” [8mm] round by

11-3/4” [299mm] long), and a coupling nut (5/16”/8mm x

7/8”/22mm).

POSITIVE FLUE CONNECTION: See your authorized Len-

nox Hearth Products dealer for necessary accessories and

installation instructions.

Positive flue connectors required for installation in Canada are

available from your Lennox Hearth Products dealer. Please

use one of the part numbers indicated below.

7112 - 8" Positive Flue Connector Ring Kit

711 - 8" to " Reducer w/ Positive Flue Connector

Lintel

Flue Outlet

Not to Scale

Brick Face

Insert Surround

Smoke

Deflector

Mechanically

Attached to

Insert

Figure 6