Installation – Lincoln Electric INNERSHIELD PRO K126-12 User Manual

Page 8

Advertising
background image

A-1

INSTALLATION

K126-10, K126-11 AND K126-12 INNERSHIELD® PRO

A-1

Duty Cycle

40%
60%
80%

100%

Process

FCAW-SS

Model

K126-10
K126-11
K126-12

Operating Temperature

Storage Temperature

-4°F to 104°F (-20C to 40C)

-40°F to 185°F (-40C to 85C)

Cable Length

10ft (3.0m)

15ft (4.5m)

Weight

7.3 lbs (3.3 kg)

11 lbs (5 kg)

Electrode Diameter Range

.035” – 3/32"

(0.8 – 2.4 mm)

Output Range (Amperes)

260A @ 100% duty cycle

350A @ 60% duty cycle

Wire Feed Speed Range

(See wire feeder

Instruction Manual)

Amperes

435
350
295
260

K126 Innershield Pro Rated Output

Physical Dimensions

Temperature Ranges

Welding Processes

SPECIFICATIONS: K126-10, -11, -12 INNERSHIELD

®

PRO

Advertising
This manual is related to the following products: