1. Connect neutral wire(white) of power cord to

center terminal block screw.

2. Connect ground wire of appliance and neutral

wire of power cord to center terminal block
screw.

3. Connect red and black wire to the left and right

terminal block screws.

4. Make sure that the strain relief screw is tightened.

and be sure that all terminal block nuts are on
tight and power cord is in right position.

5. Connect a independent ground wire from external

ground connector to proper ground.

Part 5

ELECTRICAL REQUIREMENTS FOR ELECTRIC DRYERS

lf your local codes or ordinances permit the
connection of a frame-grounding conductor to the
neutral wire, use these instructions. If your local
codes or ordinances do not allow the connection of
a frame-grounding conductor to the neutral wire,
use the instructions under Section 3: Optional
3-wire connection.

Option 2

: 3-Wire Connection with

a Power Supply Cord

• If your local codes or ordinances do not allow the

connection of a frame-grounding conductor to the
neutral wire, use the instructions under this
section.

Option 3

: Optional 3-wire

connection.