System selection 4, Quality and reliability – Lincoln Electric Multi-Weld 350 User Manual

Page 3

Advertising
background image

Description

Diameter in. (mm)

Process

Kilowatts Used

(1)

,

Flux-Cored Wire

.035 (0.9)

300 ipm WFS, 130A, 24V

3.4

Gas-Shielded

.035 (0.9)

600 ipm WFS, 195A, 30V

6.4

.045 (1.2)

300 ipm WFS, 185A, 28V

5.7

500 ipm WFS, 255A, 29V

8.1

.052 (1.3)

250 ipm WFS, 210A, 26V

6.0

450 ipm WFS, 315A, 29V

10.4

1/16 (1.6)

200 ipm WFS, 255A, 26V

7.3

350 ipm WFS, 350A

(2)

, 29V

11.2

Flux Cored Wire

5/64 (2.0)

200 ipm WFS, 280A, 30V

10.1

Self-Shielded

300 ipm WFS, 350A

(2)

, 32V

13.7

MIG Wire

.035 (0.9)

150 ipm WFS, 120A, 19V

2.5

250 ipm WFS, 175A, 22V

4.2

.045 (1.2)

125 ipm WFS, 145A, 19V

3.0

200 ipm WFS, 200A, 21V

4.6

Stick (7018)

1/8 (3.2)

130A, 27V

3.9

3/16 (4.8)

225A, 28V

6.9

Stick (7024)

3/16 (4.8)

260A, 27V

7.7

Stick (6010)

1/8 (3.2)

120A, 36V

4.7

NOTE: E6010 stick electrodes require higher

voltage to “whip” properly. Higher voltage power

sources are recommended.

Air Carbon

1/4 (6.4)

350A

(2),

, 34V

13.1

Arc Gouging

3/8 (9.5)

700A

(2),

, 34V Requires two Multi-Weld 350s in parallel.

26.2

System Selection is determined by kilowatts available on the power
source.

Note: For maximum output, set power source on Constant Current
and select maximum output. Constant Voltage power sources are not
recommended.

(1) Air Vantage and Vantage 500 output is 12 kW @ 58 volts.

(2) Vantage 300 output is 7 kW @ 58 volts.

Multi-Weld 350

www.lincolnelectric.com

[3]

A CLOSER LOOK

HOW MANY KILOWATTS DOES YOUR PROCESS REQUIRE?

SYSTEM SELECTION

4

POWER SOURCE/KILOWATTS AVAILABLE

(1)

Power Source KW = = KW input to Multi-Weld 350

(2) Maximum rated output of Multi-Weld 350.

(KW)arc1 + (KW)arc2 + (KW)arcN(simultaneous)

.91 eff.

Kilowatts Available

Power Source

@60V Output

R3R-400

12

R3R-500

12

DC-600

15

DC-655

36

DC-1000

30

DC-1500

94

Classic 300D

12

SAE-400

22

Vantage 300

(2)

4.8

Vantage 500

(1)

5

Air Vantage 500

(1)

5

• Printed circuit boards are environmentally-shielded using Lincoln's

engineered potting and protective frame trays.

• Thermostat and voltage overload protection.

• Fan-As-Needed – solid state controlled fan operates cooling fan

only when needed. Minimizes power consumption, operating noise
and dust intake.

QUALITY AND RELIABILITY

Advertising