Warning, Blower, Burner flame – Lennox International Inc. G24M SERIES User Manual

Page 5

Advertising
background image

2=CA #

UPFLOW FURNACE

BOTTOM RETURN AIR

FIGURE 4

UPFLOW FURNACE

SIDE RETURN AIR

FIGURE 5

DOWNFLOW FURNACE

FILTERS IN PLENUM RACK

FIGURE 6

Blower

Check and clean blower wheel for any debris. Blower mo-
tor is prelubricated for extended bearing life. No further lu-
brication is needed.

WARNING

Blower door must be securely in place when blower
and burners are operating. Gas fumes, which could
contain carbon monoxide, can be drawn into living
space resulting in personal injury or death.

Burner Flame

The G24M burner flame is not adjustable; however, the
flame should be inspected at the beginning of each heat-
ing season and burners should be cleaned, if necessary.
Burner flame should be blue when burning natural gas,
blue/yellow when burning propane gas.

BURNER FLAME

BURNER

FLAME

HEAT

EXCHANGER

TUBE

VEST

PANEL

FLAME APPEARS BLUE IF

BURNING NAT. GAS; BLUE/

YELLOW FOR PROPANE.

FIGURE 7