G3503-[ ] POWER WAVE 450 WATER COOLER UPGRADE KIT

4

l. Attach Power Wave machine label from retrofit

kit to its case back.

m. Stamp or etch "B" as the suffix of Power

Wave

s code number located on its rating

plate. Include this suffix for all future parts
orders.

n. Install gas cylinder(s) onto tray.

5. Select a recommended coolant and fill cooler to

specified level (see Figure 1).

6. Attach desired water-cooled accessory (gun and

wire feeder or TIG torch) to cooler

s QDs.

7. Reconnect service input power to the Power Wave:

Verify that the reconnect panel setting and

lead placement match the service voltage.

8. Prime the cooler:

a. Install the Set-up overlay.
b. Keep accessories

hose lengths horizontal,

either coiled or straight, and no higher than 4
feet of the specified coolant level (Fig. 1).

c. Switch on the Power Wave machine.
d. Press the "WATER COOLER ENABLE" button

so that the "WATER COOLER ENABLED" light
is illuminated.

e. Press the "PRIME WATER COOLER" button

until the "WATER COOLER PRESSURE" light
is steadily illuminated.

9. Check coolant level. Add more if required.

REMOVING AND INSTALLING THE G3503-[ ]
COOLER

1. Preparation:

Always switch off the Power Wave machine

power.

Always disconnect the Power Wave machine

from service input power.

2. Remove cooler assembly G3503-[ ]:

a. remove gas cylinder(s) from tray.
b. remove cooler access panel.
c. Remove both fasteners from base that hold

cooler and mounting brackets (if equipped) in
place. Remove ground lead, if present.
Carefully pull cooler assembly rearward, until
cooler

s Molex connectors are visible.

d. disconnect cooler

s connectors from the P3 and

P4 harnesses. Continue pulling the cooler out
of the Power Wave.

3. If necessary, perform periodic maintenance or ser-

vice on the cooler.

4. Reinstall cooler by reversing tasks in step 2. Be

sure to reattach ground lead, if previously removed.

5. If necessary, fill cooler with selected coolant to

specified level (see Fig. 1).

6. Attach desired water-cooled accessory (gun and

wire feeder or TIG torch) to cooler

s QDs.

7. Reconnect service input power to the Power Wave:

verify that the reconnect panel setting and lead

placement match the service voltage.

8. Prime the cooler:

a. Install the Set-up overlay.
b. Keep accessories

hose lengths horizontal,

either coiled or straight, and no higher than 4
feet of the specified coolant level (Fig. 1).

c. Switch on the Power Wave machine.
d. Press the "WATER COOLER ENABLE" button

so that the "WATER COOLER ENABLED" light
is illuminated .

e. Press the "PRIME WATER COOLER" button

until the "WATER COOLER PRESSURE" light
is steadily illuminated.

9. Check coolant level. Add more if required.

Advertising