La Crosse Technology WS-1515U-IT User Manual

Page 3

Advertising
background image

80

Air pressure

histogram

LCD SCREEN

The LCD screen is split into 5 sections displaying the following information:
1.

Time and date/ indoor temp/ second

2. Wind

data

3.

Outdoor temperature, Dew point and humidity,

4.

Air pressure, Rainfall data, Air pressure history and Weather forecast

icon.





























* When the signal from the transmitter/ or Rain sensor is successfully
received by the Weather Station, this icon will be switched on. (If not
successful, the icon will not be shown on the LCD). User can therefore
easily see whether the last reception was successful (“ON” icon) or not
(“OFF” icon). On the other hand, the short blinking of the icon shows that a
reception is being done at that time.












Outdoor temperature

or dew point

in °F or ºC

Wind direction display
and wind speed in
Beaufort scale

Calendar display

Weather tendency
indicator

Time display

Time alarm icon

Outdoor relative
humidity in %

Weather forecast
icon

Relative air pressure

display in inHg or hPa,

or total and 24h rainfall

display in inch or mm

Wind speed or gust
in mph, km/h or m/s

Wind Chill in

F or

C

Wind speed Hi
alarm icon

Outdoor Humidity
alarm icon

Outdoor temp.

alarm icon

Low battery
Indicator (rain sensor)

Low battery Indicator (Thermo-hygro)

Buzzer off indicator

Transmitter signal
reception icon

Low battery Indicator (weather center)

81

*In normal display user may press the SET key shortly to toggle between
Mode 1 and Mode 2 display:

Mode 1 : Wind speed, outdoor temperature and relative pressure reading
are shown.












Mode 2 :
Wind Gust, Dew Point temperature and Rainfall reading are
shown.











MANUAL SETTING:

The following manual settings can be changed once the SET key is
pressed and hold for about 3 seconds:

LCD contrast setting

Manual time setting

12/24 hour time display

Calendar setting

°F/ °C temperature unit setting

Wind speed unit

Rainfall unit setting

Air pressure unit setting

Relative pressure reference value setting

Weather tendency threshold value

Storm warning threshold value

Alarm On/ Off setting

LCD CONTRAST SETTING



The LCD contrast can be set within 8 levels, from "LCD 1" to "LCD 8"
(default setting is LCD 5):
1. Press

the

SET key, the contrast level digit will start flashing.

2. Use

the

+ or MIN/MAX key to adjust the level of contrast.

3. Confirm

with

the

SET key and enter the MANUAL TIME SETTING.

Wind speed icon

Outdoor temp

icon

Rel Pressure

icon

Wind gust icon

Dew point icon

Rainfall icon

In Mode 1, this reception
icon is showing the
condition of the
reception of the signal
from Thermo-hygro
transmitter

In Mode 2, this
reception icon is
showing the condition
of the reception of the
signal from Rain
sensor

Flashing

82

"Date. Month." (for 24h time display)
"Month. Date." (for 12h time display)

Année

MANUAL TIME SETTING:

You then may manually set the time of the clock by following the steps
below:



1.

The hour digit will start flashing.

2. Use

the

+ or MIN/MAX key to set the hour.

3. Press

the

SET key to switch to the minutes. The minute digit will start

flashing.

4. Use

the

+ or MIN/MAX key to set the minute.

5.

Confirm the time with the SET key and enter the 12/24 HOUR TIME
DISPLAY SETTING
.

12/24 HOUR TIME DISPLAY SETTING:





The time can be set to view as 12-hour or 24-hour format. The default time
display mode is 12-h. To set to 24-h time display:
1. Use

the

+ or MIN/MAX key to toggle the value.

2. Confirm

with

the

SET key and enter the CALENDAR SETTING.

CALENDAR SETTING:






The date default of the Weather Center is 1. 1. of year 2005. The date can
be set manually by proceeding as follows.
1.

The year digit starts flashing.

2. Use

the

+ or MIN/MAX key to set the year. The range runs from "00"

(2000) to "99" (2099).

3. Press

the

SET key to confirm the year and enter the month setting.

The month digit will start flashing.

4. Use

the

+ or MIN/MAX key to set the month.

5. Press

the

SET key to confirm the month and enter the date setting

mode. The date digit will start flashing.

6. Use

the

+ or MIN/MAX key to set the date.

7.

Confirm all calendar settings with the SET key and enter the °F/°C
TEMPERATURE UNIT SETTING
.

°F/°C TEMPERATURE UNIT SETTING





The temperature display can be selected to show temperature data in °F or
°C. (default °F)
1.

The temperature unit is flashing

2. Use

the

+ or MIN/MAX key to toggle between “°F” or “°C”.

3.

Confirm with the SET key and enter the WIND SPEED UNIT
SETTING.

Minutes flashing

Hour

flashing

Digit flashing

Flashing

83

WIND SPEED UNIT SETTING





The wind speed unit can be set as mph (mile per hour), km/h (kilometer per
hour), or m/s (meter per second). The default unit is mph.
1. Use

the

+ or MIN/MAX key to toggle between the unit “mph”, “km/h”

or “m/s”

2. Confirm

with

the

SET key and enter the RAINFALL UNIT SETTING.

RAINFALL UNIT SETTING





The rainfall unit can be set as inch or mm. The default unit is inch.
1. Use

the

+ or MIN/MAX key to toggle between the unit “inch” or “mm”

2.

Confirm the unit with the SET key and enter the RELATIVE AIR
PRESSURE UNIT SETTING

RELATIVE AIR PRESSURE UNIT SETTING






The relative air pressure can be set as inHg or hPa. The default unit is inHg.
1. Use

the

+ or MIN/MAX key to toggle between the unit “inHg" or “hPa”

2.

Confirm the unit with the SET key and enter the RELATIVE
PRESSURE REFERENCE VALUE SETTING
.

RELATIVE PRESSURE REFERENCE VALUE SETTING

Note:
The default reference pressure value of the barometer is 29.91inHg when
batteries are first inserted. For an exact measurement, it is necessary to
first adjust the barometer to your local relative air pressure (related to
elevation above sea level)
. Ask for the current atmospheric pressure of
your home area (Local weather service, www, optician, calibrated
instruments in public buildings, airport).

The relative air pressure can be manually set to another value within the
range of 27.17 to 31.90 inHg (919 to 1080 hPa) for a better reference.





1.The current relative pressure value will start flashing
2.Use the + or MIN/MAX key to increase or decrease the value. Continually

holding the key will allow the value to increase faster.

3.Confirm with the SET key and enter the WEATHER TENDENCY

SENSITIVITY VALUE SETTING.

Note:
This feature is useful for those who live at elevations above sea level, but
want their air pressure display to be based on sea level elevation.


Flashing

Flashing

Flashing

Flashing

MPH

Advertising
This manual is related to the following products: