Stove installation, Chimney termination requirements, Outside air requirements – Lopi Answer Wood Stove User Manual
Page 11
 
Stove Installation
(for qualified installers only)
11
© Travis Industries
100-01166
4040907
Chimney Termination Requirements
•
Must have an approved cap (to prevent water from entering)
•
Must not be located where it will become plugged by snow or other material
•
Must terminate at least 3' above the roof and at least 2' above any portion of the roof within 10' (see
Figure 5)
Slanted Roofs
Flat Roofs
Chimney must 
extend 3' 
above the roof
Chimney must extend 2' 
above any portion of the roof 
within 10' of the chimney
Chimney must 
extend 3' 
above the roof
Chimney must extend 2' 
above any portion of the roof 
within 10' of the chimney
Figure 5
Outside Air Requirements
•
Required for mobile homes & in certain localities (check with building officials)
•
Must not be drawn from an enclosed space (garage, unventilated crawl space)
•
Requires the optional outside air boot (for legs) or pedestal.
Optional Air Duct (must not be 
longer than 15' and at least 16 
square inches in cross section)
A hole must be cut 
through the floor 
protection and floor 
and the rodent 
screen nailed in 
place here (see the 
optional equipment 
instructions for 
exact sizes)
Outside 
Air Boot
Outside air entrance must be placed so 
it does not become blocked by snow.
When using outside air, find a location where the chimney and 
outside air hole do not interfere with structural members of the home.
Pedestal (with insulation) 
directs air to the stove.
Air may be drawn from a ventilated 
crawl space or use an air duct.
Figure 6