CARE AND OPERATION

PAGE 16

HOW TO START AND MAINTAIN A FIRE
1. Using the Air Control Tool (provided), open the

Start-Up Air Control (see Start-Up Air Control, on
page 15).

2. Adjust the primary air draft control to the full open

position (see Primary Air Draft Control on page 15).

3. Open the side fuel loading door and build your fire

directly on the grate in the firebox.
a. Place five or six loosely crumpled sheets of

newspaper in the stove.

b. Add a small amount of dry kindling randomly on

the top of the newspaper.

c. Place a few more loosely crumpled newspapers

on top of the kindling and light the bottom paper
first, then light the top paper. Once the fire is
well underway, close the door. The upper fire
should preheat the chimney and create an effec-
tive draft while the lower fire ignites the kindling.

4. After the kindling is burning well, add increasingly

larger pieces of wood until the fire is actively burn-
ing (see notes below). Leave the fuel door open
(slightly ajar for 5 minutes). Then close the stove
door. Never leave the stove unattended when the
door is open.

When loading fuel, be careful not to smother
the fire.

Load logs evenly across the base being cau-
tious not to place wood in front of the rear edge
of the log guard.

5. Once a bed of coals has been established, adjust

the primary air control to a lower setting AND
CLOSE THE START-UP AIR CONTROL.

AIR DELIVERY SYSTEMS

Tip – Using the air control tool, adjust the primary air
draft control to a medium to low setting for a slow and
more efficient burn. On higher settings, it is more effi-
cient to burn with a bright but not roaring fire.

When Refueling
1. Follow the normal procedure for refuelling descri-

bed on page 18. However, instead of cracking the
door open ½

″, open the start-up air control by pul-

ling the lever outwards. This will supply enough
primary combustion air to allow the fire to recover.


DO NOT LEAVE THE START-UP AIR CONTROL
OPEN FOR MORE THAN FIVE MINUTES. CLOSE BY
PUSHING THE LEVER INWARDS.

CI1000HT

Side Cut-A-Way View

CI2000HT

Side Cut-A-Way View




Secondary Air
Tubes (3)

Supplemental
Secondary
Air Delivery

Secondary Air is
delivered through
this opening to
ignite secondary
gases. There is no
adjustment con-
trol for this in-
take.

Start-up
Air Control.

See Start-Up Air
Control Illustra-
tion on page 15.

Primary Air
Control


Primary Air
Control

Secondary Air
Tubes (2)

Permanent
Secondary
Combustion
Air Intake.

Secondary Air is
Delivered through
this Opening to
ignite secondary
gases. There is no
adjustment con-
trol for this in-
take.

Permanent Pri-
mary Air Intake.

Supplimental Pri-
mary Air is Delivered
through this Small
Opening (to improve
efficiency). There is
no adjustment con-
trols for this intake.