8011ww, Calculite, Compact fluorescent open wall washer – Lightolier 8011WW User Manual

Page 2: Page 2 of 2 4” aperture triple tube vertical lamp

Advertising
background image

2'

18 f.c.

3'

5'

5'

18 f.c.

2’ From Wall-2’ On Center

1

14

12

14

2

17

16

17

3

18

18

18

4

16

16

16

5

12

12

12

6

10

10

10

7

7

7

7

8

6

6

6

9

4

4

4

Candlepower Distribution Downlight Spacing Ratio 1.3

Coefficients of Utilization

Footcandles On Wall: Multiple 18W Triple Tube Units

2’ From Wall-3’ On Center

1

11

6

11

2

14

9

14

3

12

12

12

4

10

11

10

5

8

8

8

6

7

7

7

7

5

5

5

8

4

4

4

9

3

3

3

2’ From Wall-4’ On Center

1

11

3

11

2

13

5

13

3

11

7

11

4

8

8

8

5

6

6

6

6

5

5

5

7

4

4

4

8

3

3

3

9

3

3

3

Footcandle values are averaged and rounded off and are based on a minimum
of five units.

% EFFECTIVE CEILING CAVITY REFLECTANCE

80

70

50

30

10

0

WALL REFLECTANCE

50 30 10

50 30 10

50

30 10

50 30 10

50 30 10

0

1

.46 .45 .44

.45 .44 .43

.43 .43 .42

.42 .41 .41

.40 .40 .39 .39

2

.43 .41 .39

.42 .40 .39

.41 .39 .38

.39 .38 .37

.38 .37 .37 .36

3

.40 .37 .36

.39 .37 .36

.38 .36 .35

.37 .36 .34

.36 .35 .34 .33

4

.37 .35 .33

.36 .34 .33

.36 .34 .32

.35 .33 .32

.34 .33 .31 .31

5

.34 .32 .30

.34 .32 .30

.33 .31 .30

.32 .31 .29

.32 .30 .29 .28

6

.32 .30 .28

.32 .29 .28

.31 .29 .27

.31 .29 .27

.30 .28 .27 .26

7

.30 .27 .26

.30 .27 .25

.29 .27 .25

.28 .26 .25

.28 .26 .25 .24

8

.28 .25 .23

.27 .25 .23

.27 .25 .23

.27 .25 .23

.26 .24 .23 .22

9

.26 .23 .22

.26 .23 .22

.25 .23 .21

.25 .23 .21

.24 .23 .21 .21

10

.24 .22 .20

.24 .22 .20

.24 .21 .20

.23 .21 .20

.23 .21 .20 .19

20% FLOOR CAVITY REFLECTANCE

ROOM

CA

VITY

RA

TIO

2

3

4

Distance

From

Ceiling

in

Feet

Distance

From

Ceiling

in

Feet

Distance

From

Ceiling

in

Feet

Lighting Data

Downlight Side

Wall Washer Side

Example: With multiple clear reflector units located 2' from wall and spaced 2'
on center (matching downlights 5' on center), the illumination on the wall 3'
down from ceiling will be 14 f.c. beneath units and 18 f.c. between units.

Calculite

®

Compact Fluorescent Open Wall Washer

8011WW

Page 2 of 2

4” Aperture Triple Tube Vertical Lamp

Lightolier

a Genlyte Thomas Company

www.lightolier.com

631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
© 2011 Genlyte Thomas Group LLC (Lightolier Division) • B0711

Job Information

Type:

Advertising