INSTALLATION

A-3

SELECT SUITAbLE LOCATION

LOCATION AND VENTILATION FOR COOLING
Place the welder where clean cooling air can freely
circulate in through the rear louvers and out through
the case sides. Dirt, dust, or any foreign material that
can be drawn into the welder should be kept at a mini-
mum. Failure to observe these precautions can result
in excessive operating temperatures and nuisance
shutdowns.

LIFTING

Both handles should be used when lifting the
Flextec™ 450. When using a crane or overhead
device a lifting strap should be connected to both han-
dles. Do not attempt to lift the Flextec™ 450 with
accessories attached to it.

STACKING

The Flextec™ 450 cannot be stacked.

ENVIRONMENTAL LIMITATIONS

The Flextec™ 450 is IP23 rated for use in an outdoor
environment. The Flextec™ 450 should not be sub-
jected to falling water during use nor should any parts
of it be submerged in water. Doing so may cause
improper operation as well as pose a safety hazard.
The best practice is to keep the machine in a dry,
sheltered area.

SAFETY PRECAUTIONS

ELECTRIC SHOCK can kill.

ONLY QUALIFIED PERSONNEL
SHOULD PERFORM THIS INSTALLA-
TION.

• TURN OFF INPUT POWER TO THE POWER

SOURCE AT THE DISCONNECT SWITCH OR
FUSE bOX bEFORE WORKING ON THIS
EQUIPMENT. TURN OFF THE INPUT POWER
TO ANY OTHER EQUIPMENT CONNECTED TO
THE WELDING SYSTEM AT THE DISCONNECT
SWITCH OR FUSE bOX bEFORE WORKING ON
THE EQUIPMENT.

• DO NOT TOUCH ELECTRICALLY HOT PARTS.
• ALWAYS CONNECT THE FLEXTEC™ 450

GROUNDING LUG (LOCATED INSIDE THE
RECONNECT INPUT ACCESS DOOR) TO A
PROPER SAFETY (EARTH) GROUND.

----------------------------------------------------------------------

WARNING

FLEXTEC™ 450

Do not mount the Flextec™ 450 over combustible
surfaces. Where there is a combustible surface
directly under stationary or fixed electrical equip-
ment, that surface shall be covered with a steel
plate at least .060” (1.6mm) thick, which shall
extend not less than 5.90” (150mm) beyond the
equipment on all sides.

-----------------------------------------------------------------------

INPUT AND GROUNDING CONNECTIONS

MACHINE GROUNDING
The frame of the welder must be grounded.
A ground terminal marked with the symbol
shown is located inside the reconnect/input
connection area for this purpose. See your local and
national electrical codes for proper grounding meth-
ods.

HIGH FREQUENCY PROTECTION

Locate the Flextec™ 450 away from radio controlled
machinery. The normal operation of the Flextec™ 450
may adversely affect the operation of RF controlled
equipment, which may result in bodily injury or dam-
age to the equipment.

CAUTION

AMPS

340

375

400

450

VOLTS

34VDC

35VDC

36VDC

38VDC

TEMPERATURES

55°C

DUTY CYCLE

100%

60%

40%

20%

HIGH TEMPERATURE OPERATION

WELDER OUTPUT RATINGS AT 55°C

ELEVATED TEMPERATURES