A-3
INSTALLATION
A-3
SELECT SUITAbLE LOCATION
LOCATION AND VENTILATION FOR COOLING
Place the welder where clean cooling air can freely
circulate in through the rear louvers and out through
the case sides. Dirt, dust, or any foreign material that
can be drawn into the welder should be kept at a mini-
mum. Failure to observe these precautions can result
in excessive operating temperatures and nuisance
shutdowns.
LIFTING
Both handles should be used when lifting the
Flextec™ 450. When using a crane or overhead
device a lifting strap should be connected to both han-
dles. Do not attempt to lift the Flextec™ 450 with
accessories attached to it.
STACKING
The Flextec™ 450 cannot be stacked.
ENVIRONMENTAL LIMITATIONS
The Flextec™ 450 is IP23 rated for use in an outdoor
environment. The Flextec™ 450 should not be sub-
jected to falling water during use nor should any parts
of it be submerged in water. Doing so may cause
improper operation as well as pose a safety hazard.
The best practice is to keep the machine in a dry,
sheltered area.
SAFETY PRECAUTIONS
ELECTRIC SHOCK can kill.
ONLY QUALIFIED PERSONNEL
SHOULD PERFORM THIS INSTALLA-
TION.
• TURN OFF INPUT POWER TO THE POWER
SOURCE AT THE DISCONNECT SWITCH OR
FUSE bOX bEFORE WORKING ON THIS
EQUIPMENT. TURN OFF THE INPUT POWER
TO ANY OTHER EQUIPMENT CONNECTED TO
THE WELDING SYSTEM AT THE DISCONNECT
SWITCH OR FUSE bOX bEFORE WORKING ON
THE EQUIPMENT.
• DO NOT TOUCH ELECTRICALLY HOT PARTS.
• ALWAYS CONNECT THE FLEXTEC™ 450
GROUNDING LUG (LOCATED INSIDE THE
RECONNECT INPUT ACCESS DOOR) TO A
PROPER SAFETY (EARTH) GROUND.
----------------------------------------------------------------------
WARNING
FLEXTEC™ 450
Do not mount the Flextec™ 450 over combustible
surfaces. Where there is a combustible surface
directly under stationary or fixed electrical equip-
ment, that surface shall be covered with a steel
plate at least .060” (1.6mm) thick, which shall
extend not less than 5.90” (150mm) beyond the
equipment on all sides.
-----------------------------------------------------------------------
INPUT AND GROUNDING CONNECTIONS
MACHINE GROUNDING
The frame of the welder must be grounded.
A ground terminal marked with the symbol
shown is located inside the reconnect/input
connection area for this purpose. See your local and
national electrical codes for proper grounding meth-
ods.
HIGH FREQUENCY PROTECTION
Locate the Flextec™ 450 away from radio controlled
machinery. The normal operation of the Flextec™ 450
may adversely affect the operation of RF controlled
equipment, which may result in bodily injury or dam-
age to the equipment.
CAUTION
AMPS
340
375
400
450
VOLTS
34VDC
35VDC
36VDC
38VDC
TEMPERATURES
55°C
DUTY CYCLE
100%
60%
40%
20%
HIGH TEMPERATURE OPERATION
WELDER OUTPUT RATINGS AT 55°C
ELEVATED TEMPERATURES