Caution – Lennox International Inc. GHR32 User Manual

Page 5

Advertising
background image

Page 5

Inspect furnace return air duct connection to ensure duct is

sealed to the furnace and terminates outside the space

containing the furnace.
Inspect the physical support of the furnace to guarantee

that it is sound without sagging, cracks or gaps around

base and it maintains seal between base and support.
Inspect and clean the condensate traps and drain.
Blower
Check and clean blower wheel for any debris. Blower moĆ

tor is pre-lubricated for extended bearing life. No further luĆ

brication is needed.

Burner Flame

Set thermostat to call for heat. Allow unit to operate for a

few minutes to establish normal burning conditions. Check

burner flame. Flame should be predominantly blue and

strong in appearance.

CAUTION

Periodically look through the flame sight glass to

check the burner flame.

Contact your Lennox dealer for a periodic unit inspection

by a qualified service technician.

Service Reminder

Call your Lennox service technician if unit is inoperative.

Before calling, always check the following to be sure serĆ

vice is required:

1 - Check that electrical disconnect switches are ON.
2 - Check room thermostat for proper setting.
3 - Replace any blown fuses or reset circuit breakers.
4 - Gas valve should be ON.
5 - Air filter should not be plugged limiting air flow.
6 - Is gas turned on at meter?
7 - Is manual main shut-off valve open?

Safety Precautions

If you discover any of the following, shut down your
unit, and contact an independent Lennox dealer for an
inspection by a qualified technician.

D

If you repeatedly hear any new or unfamiliar sounds

while your unit is operating, there may be a problem. For

example, poorly performing burners can produce unfaĆ

miliar noises.

D

If you smell any unusual odors, your unit may be operatĆ

ing improperly. For example, units can give off unfamilĆ

iar odors if components are required to operate in abĆ

normal conditions.

D

Look for visible signs of a malfunctioning unit. Examples

include unusual amounts of condensate on windows inĆ

side your house, visibly burnt components, or unusual

accumulation of rust in the unit.

D

If you experience headache, nausea, fatigue, or dizziĆ

ness, the cause could be exposure to carbon monoxide

gas. This is often misdiagnosed as the flu because

symptoms are similar. If you suffer from flu-like sympĆ

toms that are exaggerated at home, but seem to subĆ

side while you are away from the house, exposure to

carbon monoxide could be the cause.

Your vigilance may pay off in early detection of a problem
before either personal injury or property damage occurs.
Do not hesitate to contact a qualified service technician as
an investment in your well being.

Planned Service

You should expect a service technician to check the followĆ

ing items during an annual inspection. Power to the unit

must be shut off for the service technician's safety.

Burners- Must be inspected for rust, dirt, or signs of water.

Vent pipe - Must be inspected for dirt, damaged or sagging

unsupported pipe, or disconnected joints.

Unit appearance - Must be inspected for rust, dirt, signs

of water, and burnt or damaged wires components.

Blower access door - Must be properly in place and proĆ

vide a seal between the return air and the room where the

furnace is installed.

Return air duct - Must be properly attached and provide

an airtight seal to unit.

Operating performance - Unit must be observed during

operation to monitor proper performance of the unit and the

vent system.

Combustion gases - Flue products must be analyzed and

compared to the unit specifications.

Problems detected during the inspection may make it necĆ

essary to temporarily shut down the furnace until the items

can be repaired or replaced.
Pay attention to your furnace. Situations can arise beĆ

tween annual furnace inspections that may result in unsafe

operation. For instance, items innocently stored next to the

air inlet may obstruct the combustion air supply. This could

cause incomplete combustion and the production of carĆ

bon monoxide gas.