Calibration of ep devices – Lowrance electronic LMF-400 User Manual

Page 28

Advertising
background image

26

Trim Tab Sensors:

highlighting Trim Tab Sensors and pressing

ENTER,

will launch the following message: Press Enter to Reset Device Values.
To reset the Trim Tab Sensor settings to the default setting, press

ENTER

.

Calibration of EP Devices

Calibrating Fluid level is an important step to ensuring the status of
your tank is correctly transmitted over the NMEA 2000 bus.

For example: if you have an odd-shaped tank, like one that is wider at
the top than at the bottom, the float inside the tank will tell you there
is a half tank of gas when it reaches the midpoint of the tank,
regardless of the tank’s actual capacity below the midpoint. That could
cause you to run out of gas more quickly than expected. Whether the
tank is configured for Fuel, Fresh Water, Waste Water, Black Water or
Oil, calibrating the Fluid Level protects you from unpleasant surprises.

NOTE:

To run a system check for devices connected to the NMEA 2000
network, select

B

US

D

EVICES

from the System Setup menu and press

ENTER

.

A Searching Bus Devices message comes up, followed by a

list of all devices attached to the LowranceNET — the Bus Devices
list. To select an item from the bus devices list, use the

UP

and

DOWN

keys to scroll through the list. Highlight the desired category

and press

ENTER

.

To calibrate a tank:
1. Press

MENU

, select

S

YSTEM

S

ETUP

and press

ENTER

.

2. From the System Setup menu, highlight

B

US

D

EVICES

and press

ENTER

to bring up the Bus Devices list.

3. From the devices list, highlight the fluid level source you want to
calibrate, press

ENTER

, select

C

ALIBRATE

and press

ENTER

. A menu will

appear with three calibration options: 2 point, 3 point and 5 point.
To execute

2-Point Calibration:

there will be a pair of settings in the 2-

point calibration menu: Empty Level and Full Level. 2-Point calibration
is best for rectangular or square shaped tanks that allow the fuel level
sensor to provide an accurate reading of the fuel level at the top and
bottom of the tank.
1. Choose the level (

E

MPTY OR

F

ULL

L

EVEL

) that corresponds with your

tank's current fuel level and press

ENTER

.

If you choose F

ULL

L

EVEL

, the following message will appear: Calibrating

Set Tank to Full Level Press Enter.
2. Press

ENTER

and you will be taken back to the 2-point menu.

3. Press

EXIT

to return to the Bus Devices list.