Troubleshooting, Caution – Lincoln Electric IDEALARC IM420-D User Manual

Page 19

Advertising
background image

E-3

TROUBLESHOOTING

E-3

IDEALARC® DC-1000

Observe all Safety Guidelines detailed throughout this manual

If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your
Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed.

CAUTION

PROBLEMS

(SYMPTOMS)

POSSIBLE

CAUSE

RECOMMENDED

COURSE OF ACTION

Machine has maximum output but

not control.

Machine has minimum output and no

control.

Machine does not have maximum

output.

Machine has output but trips off

immediately when wire feed unit

start button is pressed.

Variable or sluggish welding arc.

Machine will not shut off.

Output control not functioning on the

machine

(1)

.

1. Output control switch (SW3) in wrong

position.

2. Output control switch faulty.

3. Open in feedback circuitry.

4. Faulty control or firing circuit P.C.

boards.

5. Output control potentiometer circuit

open (Lead 75).

1. Terminals 73, 74, 75, 76 or 77

grounded to

positive output.

1. One input fuse blown.

2. One phase of main transformer open.

3. Faulty control or firing circuit P.C.

boards.

4. Output control potentiometer defec-

tive.

5. Output control potentiometer leads

open - 76, 77, 226, 236, 237, 238.

1. Machine has either an internal or

external short circuit on the output.

2. Faulty control P.C. board.

3. Terminals 73, 74, 75, 76, 77 ground-

ed to negative output terminal.

1. Poor work or electrode connection.

2. Welding leads too small.

3. Welding current or voltage too low.

4. Defective main SCR bridge.

1. Input contactor contacts frozen.

2. Faulty 2CR relay.

1. Check position of switch.

2. Check switch and replace if faulty.

3. Check wiring and control and firing

circuit P.C. board wiring harness

plugs.

4. All light emitting diodes must be lit,

except LED4 on the control/fault

board. See P.C. board troubleshoot-

ing guide.

5. Check and replace potentiometer if

faulty. Check wiring of Lead #75.

1. Check 73, 74, 75, 76 or 77 for ground

to positive output circuit.

1. Check and replace if blown after

checking for reason for blown fuse.

2. Check for open and repair.

3. All light emitting diodes must be lit on

both P.C. boards, except LED4 on

control/fault board. See P.C. board

troubleshooting guide.

4. Check and replace if faulty.

5. Repair.

1. Check internally and externally for

any shorts and remove or repair.

2. Replace control board. See P.C.

board troubleshooting guide.

3. Check for grounded 73, 74, 75, 76,

77.

1. Check and clean all connections.

2. Check table in instruction manual.

3. Check procedures for recommended

settings.

4. Check and replace if defective.

1. Check and replace if necessary.

2. Check and replace if necessary.

(1)

If connected to an LN-9 or NA-5, disconnect leads 73, 74, 75 before troubleshooting.