UPFLOW FURNACE

SIDE RETURN AIR

FIGURE 5

Blower

Check and clean blower wheel for any debris. Blower

motor is prelubricated for extended bearing life. No

further lubrication is needed.

WARNING

Blower door must be securely in place when blower

and burners are operating. Gas fumes, which could

contain carbon monoxide, can be drawn into living

space resulting in personal injury or death.

Burner Flame

The burner flame is not adjustable; however, the

flame should be inspected at the beginning of each

heating season and burners should be cleaned, if necĆ

essary. Burner flame should be blue when burning

natural gas, blue/yellow when burning propane gas.

BURNER FLAME

BURNER

FLAME

HEAT

EXCHANGER

TUBE

VEST

PANEL

FLAME APPEARS BLUE IF

BURNING NAT. GAS; BLUE/

YELLOW FOR PROPANE.

FIGURE 6

Venting System Inspection

Annually (before heating season) inspect furnace

venting system, vent cap, heat exchanger and burnĆ

ers for corrosion, deterioration, or deposits of debris.

Remove any obstructions.
Contact your dealer for a periodic unit inspection by a

qualified service technician.

Flame Rollout Safety Switches

Your furnace is equipped with two flame roll-out safeĆ

ty switches which shut off the gas supply to the furĆ

nace in case of heat exchanger blockage. If the furĆ

nace fails to operate due to the functioning of these

safety switches, DO NOT attempt to place the furnace

into operation. Contact a qualified service technician.

Safety Reminder

Call a qualified service technician if unit is inoperaĆ

tive. Before calling, always check the following to be

sure service is required.
1 - Check that electrical disconnect switches are ON.
2 - Are access panels securely in place?
3 - Check room thermostat for proper setting.
4 - Replace any blown fuses or reset circuit breakers.
5 - Gas valve should be ON.
6 - Air filter should not be plugged limiting air flow.
7 - Is gas turned on at meter?
8 - Is manual main shutĆoff valve open?
To keep your gas heating system in peak operating

condition year after year, contact your dealer about a

planned service program.

Safety Precautions

If you discover any of the following, shut down your
unit, and contact your dealer for an inspection by a
qualified technician.

S

If you repeatedly hear any new or unfamiliar sounds

while your unit is operating, there may be a problem.

For example, poorly performing burners can produce

unfamiliar noises.

S

If you smell any unusual odors, your unit may be operĆ

ating improperly. For example, units can give off unfaĆ

miliar odors if components are required to operate in

abnormal conditions.

S

Look for visible signs of a malfunctioning unit. ExamĆ

ples include unusual amounts of condensate on winĆ

dows inside your house, visibly burnt components or

unusual dirt or rust accumulations on the vent pipe or

in the unit.