REPORT CONSOLE TROUBLE

✦ The factory setting does not report Console trouble

events to the Central Station.

STEP #108 The communicator can be programmed to report

Console trouble events using this step. These
include all conditions that light the Console’s
BATTERIES or TROUBLE indicator. It also includes low
Console backup battery.

REPORT FORCE ARMING

✦ The factory setting does not send force arming

reports.

STEP #110 The communicator can be programmed to report

force arming anytime the Console is armed with
one or more bypassed sensors using this step.

✦ The factory set reporting code for force arming is

“65” (Code 574 with Ademco).

NOTE: If force arming is enabled, and the Console

is force armed (armed with an open sensor)
remotely by telephone, or with the RA-2400
Remote Access software, the caller will be
disconnected if the communicator is enabled.

OPENING AND CLOSING REPORTS

✦ The factory setting does not send opening and

closing reports.

STEP #111 The communicator can be programmed to send an

opening report when the system is disarmed, and
a closing report when the system is armed for all
users, or just the master user using this step.

NOTE 1: For commercial installations with retail

traffi c using opening and closing reports, it is
recommended to disable quick arming to prevent
customers from arming the system.

NOTE 2: The reporting codes are fi xed for opening

and closing. A unique code is reserved for the
master user code and each of the fi ve restricted
user codes.

NOTE 3: Arming or disarming with the page

alert user code dials the supervisory number, no
opening or closing report is sent.

POINT ID REPORTING

✦ The factory setting enables Point ID and allows the

communicator to send two-digit alarm and trouble
codes for each sensor. The individual sensor that
causes an alarm or trouble report can be identifi ed
at the Central Station.

STEP #113 Point ID can be disabled using this step. The

Central Station will only receive general alarm and
trouble reports.

0 FOR NO CONSOLE TROUBLE
1 FOR CONSOLE TROUBLE

PROGRAMMING STEP #108

PROGRAM

STORE PROGRAM

0 FOR NO FORCE ARMING RPTS.
1 FOR FORCE ARMING RPTS.

PROGRAMMING STEP #110

PROGRAM

STORE PROGRAM

0 FOR NO OPEN/CLOSE REPORTS
1 FOR O/C RPTS. FOR ALL USERS
2 FOR O/C RPTS. FROM MASTER
USER ONLY

PROGRAMMING STEP #111

PROGRAM

STORE PROGRAM

0 FOR GENERAL REPORTS ONLY
1 FOR POINT ID REPORTING

PROGRAMMING STEP #113