Calculite

®

HID Downlight

C7E17VW

Page 2 of 2

7" Aperture, ED17 (Enclosed), Ceramic Metal halide, Wide Beam

Lightolier

a Genlyte Thomas Company

www.lightolier.com

631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
© 2004 Genlyte Thomas Group LLC (Lightolier Division) • AO5O4

Job Information

Type:

CEILING

80%

70%

50%

30%

WALL

70 50

30

10

50 10

50

10

50

10

0

RCR

0

.74 .74 .74 .74

.72 .72

.69 .69

.66 .66

.62

1

.71 .69 .68 .66

.68 .65

.65 .63

.63 .61

.58

2

.67 .65 .63 .61

.64 .60

.62 .59

.60 .57

.55

3

.64 .61 .58 .56

.60 .55

.58 .55

.57 .54

.52

4

.61 .57 .54 .52

.57 .51

.55 .51

.54 .50

.49

5

.59 .54 .50 .48

.53 .48

.52 .47

.51 .47

.46

6

.56 .51 .47 .45

.50 .45

.49 .44

.48 .44

.43

7

.53 .47 .44 .42

.47 .41

.46 .41

.45 .41

.40

8

.50 .44 .41 .38

.44 .38

.43 .38

.43 .38

.37

9

.47 .42 .38 .35

.41 .35

.41 .35

.40 .35

.34

10

.45 .39 .35 .33

.39 .33

.38 .33

.38 .33

.32

LUMINAIRE INPUT WATTS = 78.0

ANGLE

MEAN CP

LUMENS

0

3077

5

3138

298

10

3124

15

3095

861

20

2830

25

2407

1111

30

1960

35

1523

949

40

1036

45

609

461

50

130

55

7

33

60

1

65

0

0

70

0

75

0

0

80

0

85

0

0

90

0

70W ED17 (ENCLOSED) PHILIPS CMH, LUMEN RATING = 6000 LMS, AROMAT ELECTRONIC BALLAST, CL FINISH REFLECTOR TRIM

Coefficients of Utilization

LUMINANCE SUMMARY CD. / SQ. M.

ANGLE MEAN CD/SQ M

45

34796

55

475

65

0

75

0

85

0

** EFFICIENCY = 61.9% **

CERTIFIED TEST REPORT NO. 2412FR, DATE: JAN 12, 2004

SC = 1.0

COMPUTED BY LSI PROGRAM **TEST-LITE**

CANDLEPOWER DISTRIBUTION

ZONAL LUMENS AND PERCENTAGES

ZONE LUMENS

% LAMP %LUMINAIRE

0-30

2269

37.83

61.13

0-40

3218

53.64

86.69

0-60

3712

61.87

99.99

0-90

3712

61.88

100

40-90

494

8.24

13.31

60-90

0

0

0.01

90-180

0

0

0

0-180

3712

61.88

100

Zonal Cavity Method - Effective Floor Cavity Reflectance = 20%

30°

60°

1,500

750

2,250

3,000

CEILING

80%

70%

50%

30%

WALL

70 50

30

10

50 10

50

10

50

10

0

RCR

0

.74 .74 .74 .74

.72 .72

.69 .69

.66 .66

.62

1

.70 .69 .67 .66

.68 .65

.65 .63

.63 .61

.58

2

.67 .65 .63 .61

.64 .60

.62 .59

.60 .57

.55

3

.64 .61 .58 .56

.60 .55

.58 .54

.57 .54

.52

4

.61 .57 .54 .52

.57 .51

.55 .51

.54 .50

.49

5

.58 .54 .50 .48

.53 .48

.52 .47

.51 .47

.46

6

.56 .51 .47 .45

.50 .45

.49 .44

.48 .44

.43

7

.53 .47 .44 .42

.47 .41

.46 .41

.45 .41

.40

8

.50 .44 .41 .38

.44 .38

.43 .38

.43 .38

.37

9

.47 .42 .38 .35

.41 .35

.41 .35

.40 .35

.34

10

.45 .39 .35 .33

.39 .33

.38 .33

.38 .33

.32

LUMINAIRE INPUT WATTS = 110.0

ANGLE

MEAN CP

LUMENS

0

4614

5

4705

446

10

4685

15

4641

1291

20

4244

25

3609

1667

30

2940

35

2283

1423

40

1553

45

912

691

50

195

55

9

48

60

1

65

0

0

70

0

75

0

0

80

0

85

0

0

90

0

100W ED17 (ENCLOSED) PHILIPS CMH, LUMEN RATING = 9000 LMS, AROMAT ELECTRONIC BALLAST, CL FINISH REFLECTOR TRIM

Coefficients of Utilization

LUMINANCE SUMMARY CD. / SQ. M.

ANGLE MEAN CD/SQ M

45

52135

55

639

65

0

75

0

85

0

** EFFICIENCY = 61.8% **

CERTIFIED TEST REPORT NO. 2509FR , DATE: MAR 3, 2004

SC = 1.0

COMPUTED BY LSI PROGRAM **TEST-LITE**

CANDLEPOWER DISTRIBUTION

ZONAL LUMENS AND PERCENTAGES

ZONE LUMENS

% LAMP %LUMINAIRE

0-30

3403

37.82

61.15

0-40

4826

53.62

86.71

0-60

5565

61.84

100

0-90

5565

61.84

100

40-90

739

8.22

13.29

60-90

0

0

0

90-180

0

0

0

0-180

5565

61.84

100

Zonal Cavity Method - Effective Floor Cavity Reflectance = 20%

30°

60°

2,250

1,125

3,375

4,500