Direct – sg, sh, Sg sh joiner sg joiner, Sh run end detail – Lightolier T5 User Manual

Page 7: Lighting systems, Sh 2-lamp t5 luminous direct, Sg 1-lamp t5 luminous direct, Coefficients of utilization, How to specify

Advertising
background image

1. Housing: Extruded

aluminum. Die-cast
end plate mechani-
cally attached with no
exposed fasteners.

2. Lamping: One T5 (28

or 54 watt as speci-
fied) fluorescent lamp.
Provided by others.

3. Reflector: Die-formed

specular aluminum
reflector.

4. Shielding: Die-formed

perforated CRS.

5. Diffuser: Translucent

acrylic diffuser.

6. Louver: Straight blade

louver finished to
match housing.

Luminaire Lengths:
Individual–46 3/4" and
94 3/4". Joiner–48" and 96".

Lighting Systems

1

3

4

2

5

6

4 1/4"

2 3/4"

Coefficients of
Utilization

% Wall Reflectance

70

50

30

0

63

63

63

1

58

55

53

2

54

50

46

3

50

45

41

4

46

40

36

5

43

36

32

6

40

33

29

7

37

30

26

8

34

28

23

9

32

25

21

10

29

22

18

80% Effective Ceiling

Cavity Reflectance

20% Floor Cavity

Reflectance

How to Specify

Finish

Series SG

White

Aluminum

28 watt

SG-28-WH

SG-28-AL

54 watt

SG-54-WH

SG-54-AL

Please refer to the flap at the back of the
brochure for complete ordering instructions.

Room Cavity Ratio

55% efficiency
1 lamp F28T5
Report No. LRL299-1M

83% Direct
17% Indirect

2,000

700

500
400

200

FOOTCANDLE

20

30

50

70

100

1

2

3

4 5

7

10

20

30 40 50

70

100

200

ROOM AREA IN SQUARE FEET

NUMBER OF FIXTURES REQUIRED

300

1,000

100

1. Find room area on

vertical axis.

2. Move across chart to

footcandle curve.

3. Move down to hori-

zontal axis and read
number of luminaires
required.

SH

2-Lamp T5 Luminous Direct

1

3

4

2

5

6

5 3/4"

5 7/16"

SG

1-Lamp T5 Luminous Direct

90˚

85˚

95˚

105˚

75˚

65˚

55˚

115˚

125˚

180˚ 175˚ 165˚ 155˚ 145˚ 135˚

0˚ 5˚ 15˚ 25˚ 35˚ 45˚

500

750

250

1000

1250

0

250

90º

Coefficients of
Utilization

% Wall Reflectance

70

50

30

0

63

63

63

1

58

56

54

2

54

50

47

3

50

45

42

4

46

41

37

5

43

37

33

6

40

34

30

7

37

31

27

8

35

28

24

9

32

26

22

10

29

23

19

80% Effective Ceiling

Cavity Reflectance

20% Floor Cavity

Reflectance

Room Cavity Ratio

54.3% efficiency
2 lamp F28T5
Report No. LRL299-1C

85% Direct
15% Indirect

2,000

700

500
400

200

FOOTCANDLE

20

30

50

70 100

1

2

3

4 5

7

10

20

30 40 50

70

100

200

ROOM AREA IN SQUARE FEET

NUMBER OF FIXTURES REQUIRED

300

1,000

100

1. Find room area on

vertical axis.

2. Move across chart to

footcandle curve.

3. Move down to hori-

zontal axis and read
number of luminaires
required.

1. Housing: Extruded

aluminum. Die-cast
end plate mechani-
cally attached with no
exposed fasteners.

2. Lamping: Two T5 (28

or 54 watt as speci-
fied) fluorescent
lamps. Provided by
others.

3. Reflector: Die-formed

specular aluminum
reflector.

4. Shielding: Die-formed

perforated CRS.

5. Diffuser: Translucent

acrylic diffuser.

6. Louver: Straight blade

louver finished to
match housing.

Luminaire Lengths:
Individual–46 3/4" and
94 3/4". Joiner–48" and 96".

SG

SH Joiner

SG Joiner

Softly glowing, well-shielded direct

lighting provides generous

illumination for task

environments.

Direct – SG, SH

SH

Run End Detail

For complete specifications see
individual specification sheets.

For complete specifications see
individual specification sheets.

90˚

85˚

95˚

105˚

75˚

65˚

55˚

115˚

125˚

180˚ 175˚ 165˚ 155˚ 145˚ 135˚

0˚ 5˚ 15˚ 25˚ 35˚ 45˚

250

375

125

500

625

0

90˚

How to Specify

Finish

Series SH

White

Aluminum

28 watt

SH-28-WH

SH-28-AL

54 watt

SH-54-WH

SH-54-AL

Please refer to the flap at the back of the
brochure for complete ordering instructions.

13

Available in one and

two lamp versions.

Silhouette Direct

functions well in

work spaces,

retail stores

or libraries.

Advertising