Warning, Blower, Burner flame – Lenoxx Electronics G24M Series User Manual

Page 5: Venting system inspection, Flame rollout safety switches, Service reminder

Advertising
background image

Page 5

UPFLOW FURNACE

SIDE RETURN AIR

FIGURE 5

DOWNFLOW FURNACE

FILTERS IN PLENUM RACK

FIGURE 6

Blower

Check and clean blower wheel for any debris. Blower

motor is prelubricated for extended bearing life. No

further lubrication is needed.

WARNING

Blower door must be securely in place when blower

and burners are operating. Gas fumes, which could

contain carbon monoxide, can be drawn into living

space resulting in personal injury or death.

Burner Flame

The G24M burner flame is not adjustable; however,

the flame should be inspected at the beginning of

each heating season and burners should be cleaned,

if necessary. Burner flame should be blue when burnĆ

ing natural gas, blue/yellow when burning propane

gas.

BURNER FLAME

BURNER

FLAME

HEAT

EXCHANGER

TUBE

VEST

PANEL

FLAME APPEARS BLUE IF

BURNING NAT. GAS; BLUE/

YELLOW FOR PROPANE.

FIGURE 7

Venting System Inspection

Annually (before heating season) inspect furnace

venting system, vent cap, heat exchanger and burnĆ

ers for corrosion, deterioration, or deposits of debris.

Remove any obstructions.
Contact your Lennox dealer for a periodic unit inspecĆ

tion by a qualified service technician.

Flame Rollout Safety Switches

Your Lennox furnace is equipped with two flame roll-

out safety switches which shut off the gas supply to

the furnace in case of heat exchanger blockage. If the

furnace fails to operate due to the functioning of these

safety switches, DO NOT attempt to place the furnace

into operation. Contact a qualified service technician.

Service Reminder

Call your Lennox service technician if unit is inoperaĆ

tive. Before calling, always check the following to be

sure service is required.
1 - Check that electrical disconnect switches are ON.
2 - Are access panels securely in place?
3 - Check room thermostat for proper setting.
4 - Replace any blown fuses or reset circuit breakers.
5 - Gas valve should be ON.
6 - Air filter should not be plugged limiting air flow.
7 - Is gas turned on at meter?
8 - Is manual main shutĆoff valve open?
To keep your Lennox gas heating system in peak operatĆ

ing condition year after year, contact your independent

Lennox dealer about a planned service program.