Warning, Seasonal inspections – Lennox International Inc. G32V SERIES User Manual

Page 5

Advertising
background image

Page 5

Figure 4

BOTTOM RETURN FILTER INSTALLATION

FURNACE

BASE BOTTOM

REAR FILTER CLIP

RETURN AIR OPENING

SIDE FILTER CLIPS (2)

FURNACE

FRONT

FURNACE

BACK

4 - Clean filter with cold water and a mild soap. Direct

water through filter in the opposite direction of air

flow. Remove all soap residue.

5 - Allow filter to dry then spray with filter handicoater

prior to reinstallation. Filter handicoater is available

from your Lennox dealer as P-8-5069.

6 - Place filter in bottom of blower compartment beneath

rear filter clip. Press down on filter sides. Filter clips

flex, allowing filter to snap into place.

7 - Replace blower access panel.

WARNING

Blower door must be securely in place when blower

and burners are operating. Gas fumes, which could

contain carbon monoxide, can be drawn into living

space resulting in personal injury or death.

Side Return Air Filter Installation (Figure 5)
1 - Turn off electric power to furnace.
2 - Locate the filter door of the filter rack assembly.
3 - Using the filter door pins, pull filter door, with filter atĆ

tached, out of filter rack assembly. Remove filter door

from filter by pulling up on securing tabs.

4 - Clean filter with cold water and a mild soap. Direct

water through filter in the opposite direction of air

flow. Allow filter to dry, then spray with filter handiĆ

coater prior to reinstallation. Filter handicoater is

available from your Lennox dealer as P-8-5069.

5 - Position filter door on end of filter so that the thumb

tab side of the filter door is away from the furnace.

Check for correct air flow position. Squeeze thumb

tabs to secure filter to door.

6 - Guide filter and filter door into the filter rack

installed on side of furnace. Push door into filter

rack until secure.

Figure 5

REMOVING / REPLACING FILTER DOOR

FILTER DOOR

FILTER

FILTER DOOR

PIN

TAB

TAB

FILTER DOOR

PIN

Seasonal Inspections

A qualified service technician should inspect the comĆ

plete system each season (heating and cooling). The folĆ

lowing maintenance procedures should be conducted by

a qualified service technician. Do not attempt to service

the unit in any way.
During a seasonal check the service technician will inĆ

spect the indoor blower, the burner flame and the venting

system.
Venting System
Annually (before heating season) inspect furnace ventĆ

ing system, heat exchanger and burners for corrosion,

deterioration, or deposits of debris. Remove any obĆ

structions.
Inspect furnace venting system to make sure it is in place,
physically sound, and without holes, corrosion, or blockĆ
age. Vent connector must be in correct position, sloped
upward and be physically sound without holes or excesĆ
sive corrosion.
Inspect furnace return air duct connection to ensure duct
is sealed to the furnace and terminates outside the space
containing the furnace.
Inspect the physical support of the furnace to guarantee
that it is sound without sagging, cracks or gaps around
base and it maintains seal between base and support.
Inspect and clean the condensate traps and drain.
Blower
Check and clean blower wheel for any debris. Blower moĆ

tor is preĆlubricated for extended bearing life. No further

lubrication is needed.