Example: If 20 feet of (H) horizontal vent run
is needed, then 4 feet minimum of (V) vertical
vent will be required.

This table shows a 1 (V) to 5 (H) ratio. For
every 1 foot of (V) vertical, you are allowed 5
feet of (H) horizontal run, up to a maximum
horizontal run of 20 feet.

Example: If 20 feet of (H) horizontal vent
run is needed, then 4 feet minimum of (V)
vertical vent will be required.

This table shows a 1 (V) to 5 (H) ratio. For
every 1 foot of (V) vertical, you are allowed
5 feet of (H) horizontal run, up to a maxi-
mum horizontal run of 20 feet.

V

Minimum

feet

feet

5

(1.524)

1

(0.305)

10

(3.048)

2

(0.610)

15

(4.572)

3

(0.914)

20

(6.096)

4

(1.219)

(meters)

TABLE E

(meters)

1

1

H

+ H

1

= 20 feet (6.096 m) Max.

V

+ V +

H

+ H = 40 ft. (12.192 m) Max.

H

+ H

1

Maximum

+ V

1

V*

H

H1

V1

**Ceiling

Firestop/Spacer

(SV4.5VF)

**When using Secure Flex, use

Firestop/Spacer SF4.5VF

**Ceiling

Firestop/Spacer

(SV4.5VF)

Support Bracket

*To Top Surface

Of Fireplace

***Wall

Firestop/Spacer

***Wall

Firestop/Spacer

***Use Firestop/Spacer SV4.5HF

or SF4.5HF when using Secure

Vent or Secure Flex respectively.

Use Firestop/Spacer SV4.5HF5

or SF4.5HF5 when using Secure

Vent or Secure Flex on horizontal
vent runs for the MPLDV35/40/45

with a center line lower than 48”

(1219 mm) above the fireplace

top wrapper surface. In all cases
the firestop/spacer provided with
the termination may be used with

the termination, frame to 5”

clearance where applicable.

HORIZONTAL VENT FIGURES/TABLES (CONTINUED)

Figure 33

- Top Vent - THREE 90 DEGREE ELBOWS - ELBOW CONNECTION NOT DIRECTLY AT APPLIANCE

Figure 32

- Top Vent - TWO 90 DEGREE ELBOWS - ELBOW CONNECTION NOT DIRECTLY AT APPLIANCE

See

Table 3 on page 18 as an aid in venting component selection for a particular range of exterior wall thicknesses.

See

Table 3 on page 18 as an aid in venting component selection for a particular range

of exterior wall thicknesses.

H

+ H

1

Maximum

V Minimum

feet

feet

5

(1.524)

1

(0.305)

10

(3.048)

2

(0.610)

15

(4.572)

3

(0.914)

20

(6.096)

4

(1.219)

V +

H

+ H

1

= 40 feet (12.2 m) Max.

H

+ H

1

= 20 ft. (6.096 m) Max.

TABLE D

(meters)

(meters)

Square termination (SV4.5HT-2) shown.

Square termination (SV4.5HT-2) shown.

V*

H

H1

***Ceiling

Firestop/Spacer

(SV4.5VF)

***Note - When using

Secure Flex, use

Firestop/Spacer SF4.5VF

Support Bracket

*

To Top Surface Of

Fireplace

**Wall

Firestop/Spacer

**Wall

Firestop/Spacer

**Use Firestop/Spacer SV4.5HF or SF4.5HF when

using Secure Vent or Secure Flex respectively. Use

Firestop/Spacer SV4.5HF5 or SF4.5HF5 when using

Secure Vent or Secure Flex on horizontal vent runs

for the MPLDV35/40/45 with a center line lower than

48” (1219 mm) above the fireplace top wrapper

surface. In all cases the firestop/spacer provided

with the termination may be used with the

termination, frame to 5” clearance where applicable.