Lightning Audio 7532 User Manual

Page 88

Advertising
background image

Technical data

Radar Tank Gauge

88

Installation and Operations Manual

Auxiliary energy

Electrical connection

Housing T 12 with separate terminal compartment.

Load HART

Minimum load for HART communication: 250

Cable entry

Cable gland: M20x1.5 or Pg13.5

Cable entry: G ½ or ½ NPT

Supply voltage

See page 28

Power consumption

Max. 330 mW at 16 V, max. 500 mW at 24 V, max. 600 mW at 30 V.

Current consumption

Max. 21 mA (50 mA inrush current).

Power supply

For stand alone operation recommended via e.g. Varec RN 221N/Z.

Performance characteristics

Reference operating
conditions

According to OIML R85:

• Temperature = –25…+55 °C (-13…+131 °F)

• Atmospheric pressure

• Relative humidity (air) = 65 % ±15%

• Medium properties: e.g. medium with good reflectivity and calm

surface.

• Tank diameter: signal beam hits the tank wall only at one side.

Note!

No major interference reflections inside the signal beam.

Maximum measured
error

Absolute accuracy: 0.5 mm (2σ value)

Inventory Control Versios: ±3 mm

Proof of accuracy for
custody transfer ver-
sions

The accuracy of each 7500 RTG is established through a calibration

certificate that records the absolute and relative error at 10

equidistant points during the final test. For stilling well measurements

with 7532 RTG, a NMI / PTB calibrated tape with an absolute accuracy

of 0.25 mm is used.

Each 7500 RTG is delivered with the PTB and NMi type approval.

Additional initial factory verifications for custody applications are

available on demand for all 7500 RTG.

Maximum fill speed

By the first pass trough of measuring range: 100 mm/min., after it

unlimited.

Non-repeatability

0,3 mm (1/64")

Hysteresis

0.3 mm

Resolution

digital: 0.1 mm

analogue: 0.03 % of measuring range

Settling time

Typical 15 sec

Long-term drift

The long-term drift is within the specified accuracy.

Influence of ambient
temperature

Within the specified accuracy according to OIML R85.

Software reliability

The software used in the 7500 RTG fulfills the requirements of OIML

R85. This particularly includes:

• cyclical test of data consistency

• non-volatile memory

• segmented data storage

The 7500 RTG continuously monitor the compliance with accuracy

requirements for custody transfer measurements according to OIML

R85. If the accuracy cannot be maintained, a specific alarm is

generated on the local display and via the digital communication.

Advertising