Servicing the Filter

Inspect and clean air filters each month. Filters must
be cleaned when dirty to assure proper furnace opĆ
eration and maintain efficiency.

A-Cleaning Reusable Foam Filter
1- Turn off electrical power to furnace.
2- Remove blower access panel. Wait for blower to stop.
3- Remove filter by sliding up and out of channel.
4- Wash filter with water and a mild detergent. For inĆ

creased efficiency, filter media should be sprayed with
Filter Handicoater when dry. Filter Handicoater is RP
products No. 418 and is available as Lennox part No.
P-8-5069. See table 1 for replacement filters.

TABLE 1

G21 Model No.

Filter Size

Filter Part

No.

All Q-40,-60,

Q3-80, Q4-80 and

V3-60, -80 units

16" x 25"

(406 x 635mm)

P-8-7822

Q5-80 and all

Q-100 units: and

V5-80,-100 units

20" x 25"

(508 x 635mm

)

P-8-7831

5- Reinstall filter. Slide filter into top channel and drop

into lower channel.

IMPORTANT-Do not replace foam reusable filters
with throw-away type filters.

6- Replace blower access panel.

Lubrication

Motors are prelubricated for extended bearing life; no
further lubrication is required.

Service

At the beginning of each heating season, the system
should be checked as follows:
1- Examine the termination ends of the intake and exĆ

haust lines for obstructions or blockages.

2- Check the intake and exhaust lines for holes, sagĆ

ging or broken isolation hangers. If a sag is found in
either line, raise the line and support it with an isolaĆ
tion hanger. Replace any damaged isolation hangĆ
ers.

3- The return air duct connection should be sealed to

the furnace casing and terminate outside the space

containing the furnace.

4- Check the physical support of the furnace. It should

be sound without sagging, cracks, gaps, etc., around
the base so as to provide a seal between the support
and the base.

5- Check that there is no obvious signs of deterioration

of the furnace.

6- Inspect and clean condensate drain system for free

flow of condensate.

IMPORTANT-If a change in the sound level of the unit

is detected or there is evidence of condensate leakĆ
age around the unit, contact your Lennox service
technician.