SNUBBER AND BLEEDER RESISTOR TEST

(continued)

TROUBLESHOOTING & REPAIR

TEST PROCEDURE

1. Remove main input supply power to the

machine.

2. With the 3/8" nut driver, remove the 4

screws that hold the handle to the machine.

3. Remove the rubber gasket (cover seal) from

the lift bail.

4. With the 5/16" nut driver, remove the sheet

metal screws from the case top.

5. With the 5/16" nut driver, remove the

screws holding the right and left case sides.
Remove the case sides by lifting up and
out.

6. Perform the Capacitor Discharge Proce-

dure described earlier in this section of the
manual.

Before continuing with the
test procedure, perform the
capacitor discharge proce-
dure to avoid electric shock.

7. Perform the following tests on the four

switch boards:

Switch Board 1: (Switch Board 1 is Marked
CAP 1 on the Switch Board Assembly
Connection Decal - See Figure F.24.
)

A. Remove quick connect terminals #401,

#402, #9, and #12 from switch board 1.

B. With the volt/ohmmeter, check for 25

ohms resistance between lead #401 and
#12E.

If the measurement reads between 20 and
30 ohms, resistor R1 and leads #401 and
#12E are okay. Go to step C.

If the measurement does not read between
20 and 30 ohms, check for continuity in
leads #401 and #12E. Then test for 25
ohms resistance across R1 directly. If the
measurement does not read between 20
and 30 ohms, replace resistor R1.

C. With the volt/ohmmeter, check for 25

ohms resistance between lead #402 and
#9E.

If the measurement reads between 20 and
30 ohms, resistor R2 and leads #402 and
#9E are okay. Go to step D.

If the measurement does not read between
20 and 30 ohms, check for continuity in
leads #402 and #9E. Then test for 25
ohms resistance across R2 directly. If the
measurement does not read between 20
and 30 ohms, replace resistor R2.

D. With the volt/ohmmeter, check for 7.5 K-

ohms resistance between lead #12L (12E)
and #9L (9E).

If the measurement reads between 6.75
and 8.25 K-ohms, resistor R9 and leads
#12L(12E) and #9L (9E) are okay. Go to
step E.

If the measurement does not read between
6.75 and 30 K-ohms, check for continuity
in leads #12L (12E) and #9L(9E). Then test
for 7.5 K-ohms resistance across R9
directly. If the measurement does not read
between 6.75 and 8.25 K-ohms, replace
resistor R9.

E. Reconnect quick connect terminals #401,

#402, #9, and #12 on switch board 1.

Switch Board 2: (Switch Board 2 is Marked
CAP 2 on the Switch Board Assembly
Connection Decal - See Figure F.24.
)

A. Remove quick connect terminals #403,

#404, #9, and #12.

B. With the volt/ohmmeter, check for 25

ohms resistance between lead #403 and
#12F.

If the measurement reads between 20 and
30 ohms, resistor R3 and leads #403 and
#12F are okay. Go to step C.

If the measurement does not read between
20 and 30 ohms, check for continuity in
leads #403 and #12F. Then test for 25
ohms resistance across R3 directly. If the
measurement does not read between 20
and 30 ohms, replace resistor R3.