Step 16. Turn on gas supply and test for gas leaks using a gas leak test

solution (see Test Procedure on Page 16 of the Installation and

Operation Manual).

Step 18. Reinstall the log set and glass door assembly. See Page 10

(Log Set Installation) and Page 22 (Door Assembly Installation)

in the Installation and Operation Manual.

Step 19. Light the appliance per the lighting instructions label on ap-

pliance (located below glass door) or lighting instructions on

Page 17 of the Installation and Operation Manual. Inspect for

proper pilot and burner flame appearances (see Figures 15 and

16 below). Also see Flame Color and Behavior and Inspect The

Pilot System For Proper Flame on Page 18 of the Installation

and Operation Manual.

Figure 16 - Burner Flame Appearance

No Blue Flame

Center

Soot at

Flame Tip

Dark Orange

Flame

IMPrOPErLy

BurNING FLaME

Soot above

Flame Tip

No Soot at

Flame Tip

PrOPErLy

BurNING FLaME

Semi-Transparent

yellow Flame

Blue Flame

Center

Ports on Pan

Burner assembly

Figure 15 - Proper Pilot Flame Appearance

Safety Label

Figure 14

Inlet Gas Supply Pressure

Fuel #

Minimum

Maximum

Desired

Nat.

Gas

5" wC/po. C.E

(1.24 kPa)

10.5" wC/po. C.E

(2.61 kPa)

7" wC/po. C.E

(1.74 kPa)

Manifold Gas Supply Pressure

Fuel #

Low

high

Natural

Gas

(Lo) 1.8" wC/po. C.E

(0.45 kPa)

(hi) 3.5" wC/po. C.E

(0.87 kPa)

Step 14. Re-Install burner, and make sure air shutter is 1/8” open for

Natural Gas (see Figure 13). The proper air shutter adjustment

may need to be adjusted from standard depending upon variables

in the installation. After step 19, with the appliance lit and fully

warmed up, evaluate the burner flame appearance and re-adjust

air shutter for proper flame appearance, if necessary.

Figure 13

Check air Shutter

for Proper Gap

Through This hole

Burner

Step 15.

35,000 BTu

If you are using the #34 orifice remove the sticker on the label

to show “VISION 35” on the Label. The label is located on the

inside the lower flip down control door (see Figure 14).

25,000 BTu

If you are using the #42 orifice, adhere the VISION 25 sticker

over the VISION 35 on the safety label. The label is located on

the inside the lower flip down control door (see Figure 14).

Step 17. Using a manometer, test the inlet and manifold gas pressure

per instructions in the Installation and Operation Manual (Page

16) and as shown in the following 2 tables.

Sticker

4

Printed in u.S.a. © 2007 Lennox hearth Products

P/N 775,236M rEV. B 03/2008

Lennox reserves the right to make changes at any time, without notice, in design,

materials, specifications, prices and also to discontinue colors, styles and products.

Consult your local distributor for fireplace code information.

1110 west Taft avenue • Orange, Ca 92865

NOTE: DIAGRAMS AND ILLUSTRATIONS ARE NOT TO SCALE.

Advertising