Lux Products T10-1141SA User Manual

Installation & operation, Heating only thermostat

Advertising
background image

© 2007 LUX PRODUCTS CORPORATION. ALL RIGHTS RESERVED

ELECTRICAL RATING.............24 Vac (30 Vac Maximum)
SWITCH ACTION ............................Open Contact Switch
ANTICIPATOR RATING................................0.15A to 1.2A
TEMPERATURE RANGE...............................50°F to 90°F

T10-1141SA

HEATING ONLY THERMOSTAT

52014

INSTALLATION & OPERATION

1). THERMOSTAT LOCATION

For accurate temperature control and comfort, correct

location is very important. On new installations, the

guidelines listed below should be followed as closely as

possible. When replacing an old thermostat, install the new

one in the same location unless these conditions suggest

otherwise.

1. Locate the thermostat on an inside wall about five feet

above the floor, where it is easy to install and adjust. It

should be in a room that is used often, such as a

family room.

2. Do not install it where there are unusual heating

conditions, such as direct sunlight, close to a lamp,

radio, television, radiator, register, near a fireplace, or

other heat producing appliance. Also, check for hot

water pipes within the wall, or a stove on the other

side of the wall.

3. Do not locate in unusual cooling conditions, such as on

an outside wall, or one separating an unheated room, or

in drafts from stairwells, doors, or windows.

4. Do not locate in a damp or humid area. This can

shorten thermostat life due to corrosion.

5. Do not locate where air circulation is poor, such as in

a corner, alcove, or behind an open door.

6. Do not install until all construction work and painting

have been completed.

2) TOOLS REQUIRED

Wirestripper or knife, drill with

3

16

" bit, screwdriver, level

and a pencil.

3) REMOVING OLD THERMOSTAT

Please read all instructions carefully. As you complete

each step, check the adjoining square

■■

✓.

■■

Disconnect electricity and turn off gas to the heater.

■■

Remove cover from old thermostat.

■■

Loosen all screws.

■■

Disconnect wires from thermostat, making sure they do

not fall back inside the wall.

■■

Strip insulation

3

8

" from wire ends and clean off any

corrosion.

■■

Fill wall opening with non-combustible insulation to

prevent drafts from

affecting thermostat.

4) INSTALLING NEW THERMOSTAT

■■

Place new decorative wall plate (if supplied), Figure 3,

over wall opening. Decorative wall plate can optionally

be left off.

■■

Remove Front Cover of new thermostat by inserting a

finger in the side of the thermostat and gently prying

away each corner. Place Base, Figure 2, on wall plate

over wall opening. Mark wall with pencil at mounting

holes as shown in Figure 2. Now lay wall plate and

base to the side.

■■

Drill two holes with

3

16

" bit, 1" deep.

■■

Insert plastic screw anchors into drilled holes, flush

with wall surface.

■■

Bring wires through large hole in decorative wall plate

and through Hole For Wires in Base.

■■

Fasten Base loosely to wall using two mounting

screws. Place a level against the bottom of the Base,

adjust until it is level and then tighten mounting screws

to secure the Base.

SPECIFICATIONS

INSTALLATION AND

OPERATING INSTRUCTIONS

Advertising
Table of contents