UPFLOW FURNACE SIDE RETURN AIR

FIGURE 4

DOWNFLOW FURNACE

FILTERS IN PLENUM RACK

FIGURE 5

Blower

Check and clean blower wheel for any debris. Blower moĆ
tor is prelubricated for extended bearing life. No further luĆ
brication is needed.

WARNING

Blower door must be securely in place when blower

and burners are operating. Gas fumes, which could

contain carbon monoxide, can be drawn into living

space resulting in personal injury or death.

Burner Flame

The G27M burner flame is not adjustable; however, the

flame should be inspected at the beginning of each heatĆ

ing season and burners should be cleaned, if necessary.

Burner flame should be blue when burning natural gas.

BURNER FLAME

BURNER

FLAME

HEAT

EXCHANGER

TUBE

VEST

PANEL

FLAME APPEARS BLUE IF

BURNING NAT. GAS.

FIGURE 6

Venting System Inspection

Annually (before heating season) inspect furnace venting

system, vent cap, heat exchanger and burners for corroĆ

sion, deterioration, or deposits of debris. Remove any obĆ

structions.

Contact your Lennox dealer for a periodic unit inspection

by a qualified service technician.

Flame Rollout Safety Switches

Your Lennox furnace is equipped with two flame roll-out

safety switches which shut off the gas supply to the furĆ

nace in case of heat exchanger blockage. If the furnace

fails to operate due to the functioning of these safety

switches, DO NOT attempt to place the furnace into opĆ

eration. Contact a qualified service technician.

Service Reminder

Call your Lennox service technician if unit is inoperative.

Before calling, always check the following to be sure serĆ

vice is required.
1 - Check that electrical disconnect switches are ON.
2 - Are access panels securely in place?
3 - Check room thermostat for proper setting.
4 - Replace any blown fuses or reset circuit breakers.
5 - Gas valve should be ON.
6 - Air filter should not be plugged limiting air flow.
7 - Is gas turned on at meter?
8 - Is manual main shutĆoff valve open?
To keep your Lennox gas heating system in peak opĆ

erating condition year after year, contact your indeĆ

pendent Lennox dealer about a planned service proĆ

gram.