LG QHW 15 User Manual

Page 15

Advertising
background image

- 11 -

SECTION 8 RS-232 OUTPUT


The QHW Series of scales can be ordered with an optional RS-232 output.

Specifications:

RS-232 output of weighing data
ASCII code
4800 Baud
8 data bits
No Parity


Connector: 9 pin d-subminiature socket
Pin

2

Output

Pin 3 Input, not used at this time

Pin 5 Signal Ground


Data Format for normal weighing operations, parts counting or recalling of totals from
memory will all be different. Examples follow:

Normal Output

When percent weighing the output is the weight shown in percent only.

GS 1.234kg GS for Gross weight, NT for net weight and a unit of
weight
No.. 1

This number increments every time a new value is

stored in memory
Total 1.234kg The total value stored in memory
<lf> Includes 2 line feeds
<lf>

GS 100.00%

GS for Gross weight, NT for net weight and a unit of weight

<lf> Includes 2 line feeds
<lf>