10

Installation

(for qualified installers only)

© Travis Industries

100-01163

4041129

Drafting Performance

This appliance relies upon natural draft to operate. External forces, such as wind, barometric pressure,
topography, or factors of the home (negative pressure from exhaust fans, chimneys, air infiltration, etc.),
may adversely affect draft. Travis Industries can not be responsible for external forces leading to less
than optimal performance.

Leveling Bolt Installation

Two leveling bolts are included to level the insert if the fireplace has a stepped-up hearth. To install, raise
the rear of the insert up and insert the leveling bolts into the holes in the rear corners of the insert. Adjust
the bolts until they extend the same height as the hearth steps up. After the insert is installed, fine-tune
the leveling bolts to level the insert (see Figure 4).

This distance is the

hearth step-up. The

leveling bolts should

stick out this far from the

base of the insert.

Fireplace

Hearth

The leveling bolts go

into the holes at the

rear corners of the

insert.

Figure 4

Blower Installation

The included blower is fragile and should be installed last (see the directions below).

Remove the two

screws underneath the

ashlip with a 3/8"

nutdriver. Align the

blower under the

ashlip and replace the

two screws to secure.