Adjustment instructions, Safety precautions, Test equipment required – LG Color TV CT-25 User Manual

Page 9

Advertising
background image

- 9 -

¡

Safety Precautions

1. It is safe to adjust after using insulating transformer between

the power supply line and chassis input to prevent the risk of
electric shock and protect the instrument.

2. Never disconnect leads while the TV receiver is on.
3. Don't short any portion of circuits while power is on.
4. The adjustment must be done by the correct appliances.
5. Unless otherwise noted, set the line voltage to 230Vac

¡

10%, 50Hz.

5. The adjustment of TVshould be performed after warming up

for 15 minutes.

¡

Test Equipment required

1. RF signal generator (with pattern generator)
2. DC Power Supply
3. Multimeter (volt meter)
4. Oscilloscope
5. Color analyzer

¡

PIF (Picture Intermediate Frequency) Adjustment

1) Connect the measuring equipment to the Main Board as

shown in Fig.1.

2) Set RF frequency and output level of RF SIGNAL

GENERATOR as shown Table 1.

3) Turn off S1 and S3 and on S2.
4) Adjust L104 so that the DC voltage may be 2.4

¡

0.05Vdc.

(Table 1)

¡

LÕ VCO Adjustment (For SECAM-LÕ MODEL)

1) Connect the measuring equipment to the Main Board as

shown in Fig.1.

2) Set RF frequency and output level of RF SIGNAL

GENERATOR as shown Table 1.

3) Turn on S1,S3 and off S2.
2) Adjust VR122 so that the DC Voltage may be 2.4

¡

0.05Vdc.

¡

RF AGC (Automatic Gain Control) Adjustment

1) Input PAL-B/G 05 CH.
2) Connect Multimeter to TP2(J15),AGC adjustment point.
3) Adjust VR121 until the voltage of Multimeter becomes

2.5

¡

0.1V.

¡

Screen Voltage Adjustment

1) Tune the RF Modulator to receive a PAL or SECAM signal.
2) Press MIX button on remote controller for Service to get into

the Screen Adjust Mode.

3) Adhere the Color Analyzer on the White window of CPT

face.

4) Adjust Screen Volume of FBT so that the luminance of White

window is 12

¡

1 FL.

¡

Focus Adjustment

1) Tune the TV set to receive a digital pattern.
2) Adjust the upper Focus volume of FBT for the best focus of

vertical line B.

3) Adjust the lower Focus volume of FBT for the best focus of

area A.

4) Repeat above step 2) and 3) for the best overall focus.

IC101

TDA4470

TP1(VCO)

IC102(KI7805)

22

7

13

14

1

0.01uF

JP1

L104

9V

Power-
Supply

V

Multimeter or Oscilloscope

JP2

38.9MHz
34.25MHz

(B/G,D/K,I,L)
(SECAM-L')

100 ohm

S1

5V

4.7 Kohm

S3

S2

JP3

100 ohm

Q122

VR122

R108

R144

Test Point

: TP1

Adjust

: L104

Test Point

: TP1

Adjust

: VR122

Frequency

38.9MHz

34.25MHz

System

B/G,D/K/I,SECAM-L

SECAM-LÕ

Modulation

OFF

OFF

Output level

10mVp-p

10mVp-p

Adjust

L104

VR122

Fig. 1 : Connection Diagram of Equipment for PIF Adjustment

ADJUSTMENT INSTRUCTIONS

Test Point

: TP 2(J15)

Adjust

: VR121

Test Point

: CPT Face

Adjust

: Screen Control of FBT

Test Point

: Observing Display

Adjust

: Focus control of FBT