Troubleshooting, Troubleshooting -2 – Lenovo L171p User Manual

Page 20

Advertising
background image

3-2

ThinkVision L171p Flat Panel Monitor User’s Guide

Troubleshooting

If you have a problem setting up or using your monitor, you might be able to solve it
yourself. Before calling your dealer or IBM, try the suggested actions that are
appropriate to your problem.

Video input (Digital)

Interface

Input Signal

Horizontal addressability

Vertical addressability

Clock frequency

DVI

VESA TMDS (Panel Link™)

1280 pixels (max)

1024 lines (max)

135 MHz

Communications

VESA DDC

CI

Supported Display Modes
(VESA Standard modes
between noted ranges)

Horizontal frequency

Vertical frequency

30 kHz - 81 kHz

56 Hz - 76 Hz

Native Resolution

1280 x 1024 at 60 Hz

Temperature

Operating

Storage

Shipping

10

° to 35° C (5° to 95° F)

-20

° to 60° C (-4° to 140° F)

-20

° to 60° C (-4° to 140° F)

Humidity

Operating

Storage

Shipping

10% to 80% non-condensing

5% to 95% non-condensing

5% to 95% non-condensing

Table 3-2.

Troubleshooting

Problem

Possible cause

Suggested action

Reference

The words "Out
of Range" are
shown on the
screen, and the
power indicator
is flashing green.

The system is set to a
display mode which
is not supported by
the monitor.

If you are replacing an
old monitor, reconnect it
and adjust the display
mode to within the
specified range for your
new monitor.

If using a Windows
system, restart the system
in safe mode, then select a
supported display mode
for your computer.

If these options do not
work, contact the IBM
Support Center.

“Selecting a
supported display
mode” on page 2-6

Table 3-1.

Monitor specifications for type-model 9417-Hxx