Once you've determined the proper location for the unit, place the sen-

sor on the transom. The bottom of the bracket should be flush with the

hull's bottom. Using the sensor as a template, mark the hull for the

screws' pilot holes. Drill four 1/8" holes, one in each end of the slots.

Mount the sensor to the hull using #8 stainless steel wood screws (not
included). Use a high quality, marine grade above- or below-waterline

sealant to seal the screws. Make sure the sensor is flush with the bot-

tom of the hull and tighten the screws.

Stern view showing good location for mounting sensor on transom.

Speed sensor mounting configuration:

side view (left) and rear view (right.)

If the base of the transom has a radius, fill the gap between the tran-

som and the sensor with the sealant. This will help ensure a smooth

water flow.

Route the sensor's cable through or over the transom to the sonar unit.

If you need to drill a hole in the transom to pass the connector through,

the required hole size is 7/8".

CAUTION:

If you drill a hole in the transom for the cable, make sure it is
located above the waterline. After installation, be sure to seal the
hole with the same marine grade above- or below-waterline seal-
ant used for the screws.

Good location

Transom