Wes series 2x2, Cleanguard wet location, Options & accessories – Lightolier Cleanguard Wet Location WES Series 2X2 User Manual

Page 2: Specifications, Photometry, Ordering information, Job information type, Lightolier

Advertising
background image

VOLTAGE:
120 or 277

BALLAST TYPE:

1-2 Lamp Mag. T12

LE

<

20THD

<

10THD

1 & 2 Lamp Elec. T8

SO*

H

I

*

1-2 Lamp Elec. T8

SO*

H

I

*

1-2 Lamp Elec. TT5

SB*

I

B*

(40 Watt)

1-3 Lamp Elec. TT5

X3*

I

3*

1-4 Lamp Elec. T8

O4*

H4*

LOL Dimming (T8)

PS

LOL Dimming (TT5)

PB

*Instant Start Standard

OPTIONS:

Add appropriate suffix to

catalog no., ie: (GLR)

CLEANGUARD WET LOCATION

WES SERIES 2X2

Page 2 of 2

2' x 2' RECESSED FLUORESCENT, FOR WET LOCATIONS, COVERED CEILING USE

2 LAMP, T8 OR T12

Lightolier

a Genlyte Thomas Company

www.lightolier.com

Technical Information: (978) 657-7600 • Fax (978) 658-0595
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
© 2002 Genlyte Thomas Group LLC (Lightolier Division)
A0902

SECTION 6/Folio N30-11

Job Information

Type:

OPTIONS & ACCESSORIES

SPECIAL LENSES: Substitute VI for VA (standard) .125" nominal pattern 12
with 6.8 oz. average weight per square foot.
PLASTER FRAME: Catalog number: PF22.
CONTINUOUS ROW INSTALLATION: For F type fixtures, half-width flanges
are required between fixtures. Order Catalog Number: S2FC TRIM (each joint).
RADIO INTERFERENCE FILTER 120 or 277 volt, 50 or 60 Hz. One per fixture
is standard. SUFFIX: RF.
FUSING:

Internal fast-blow fusing. SUFFIX: GLR.
Internal slow-blow fusing. SUFFIX: GMF.

ELECTRICAL/WIRING OPTIONS: Consult factory.
DRYWALL KIT: Order Catalog Number: FK91X4. Request Folio OA30-10.
CHICAGO PLENUM: SUFFIX: CP.

SPECIFICATIONS

PERFORMANCE: In an installation of 2 lamp 31W luminaires in a room cavity
ratio of 1, reflectance 80% ceiling, 50% wall, 20% floor, the C.U. shall not be
less than .75. To prevent glare the VCP shall be not less than 40 either length-
wise or crosswise (at 100fc level) and the average brightness at 65° shall not
exceed 2629 candelas per square meter. To control veiling reflections, luminaire
output in the 30°-90° zone shall not be less than 67.4%.

MATERIALS: Chassis parts are die-formed code gauge cold rolled steel.
Housing with side rails hemmed over and housing ends turned-in for
safe handling.
FINISH: Chassis exterior—black baked polyester enamel. Cavity—white
baked polyester enamel minimum 86% reflectance. Phosphate undercoating.
LENSES: VA (standard) extruded virgin acrylic, 3/16" square based female
cones, running 45° to the panel edge, .095" nominal thickness (similar to pat-
tern 12). VI (optional) .125" nominal pattern 12 with 6.8 oz. average weight per
square foot.
ELECTRICAL: Thermally protected class “P” ballast C.B.M. approved, non PCB.
If K.O. is within 3" of ballast, use wire suitable for at least 90°.
LABELS: I.B.E.W./UL and C-UL.

PHOTOMETRY

MODEL NO. WES2GFSVA26U

coefficients of utilization — zonal cavity method

(effective floor cavity reflectance 0.20)

RF

20

20

20

RC

80

50

30

RW

70

50

30

50

30

10

50

30

10

1

79

75

73

71

69

67

68

66

65

2

72

67

62

63

59

56

61

58

55

3

66

59

54

56

52

48

54

51

47

4

61

53

47

50

46

42

49

45

41

5

56

48

42

45

40

37

44

40

36

6

52

43

37

41

36

32

40

36

32

7

49

39

33

38

33

29

37

32

29

8

45

36

30

35

30

26

34

29

26

9

42

33

28

32

27

24

31

27

23

10

40

31

25

30

25

21

29

25

21

visual comfort probability

(rated lumens per lamp 3150.)

room size

ceiling height

ceiling height

W

L

8.5

10.0

13.0

16.0

8.5

10.0

13.0

16.0

20

20

56

60

66

73

53

57

63

70

20

30

50

53

57

63

46

50

54

60

20

40

47

49

53

57

42

45

49

53

20

60

43

46

49

52

38

41

44

48

30

20

58

61

66

72

56

60

63

69

30

30

51

54

57

62

48

51

54

59

30

40

47

49

52

55

43

46

49

52

30

60

43

46

47

50

38

41

43

47

30

80

42

44

45

48

36

39

40

44

40

20

59

63

67

71

58

62

65

70

40

30

52

55

58

62

50

53

56

60

40

40

48

50

52

55

44

47

50

53

40

60

44

46

48

50

39

42

44

47

40

80

42

44

44

47

37

39

40

43

40

100

42

43

43

45

36

38

38

41

60

30

53

56

59

63

51

55

57

61

60

40

48

51

53

56

46

49

51

54

60

60

44

47

48

50

40

43

44

48

60

80

42

44

44

47

38

40

40

43

60

100

42

43

42

45

37

38

38

41

100

40

51

53

55

58

49

52

54

57

100

60

47

49

49

52

44

46

47

50

100

80

44

46

46

48

41

42

43

46

100

100

43

44

43

46

39

40

40

41

room cavity ratio

luminaries lengthwise

luminaries crosswise

ORDERING INFORMATION

Explanation of Catalog Number. Example: WES2GFSVA26U120SOGLR

WE

CLEANGUARD

WET

LOCATION

S

STATIC

2

FIXTURE

WIDTH

CEILING TYPE:

G= Grid (lay-in T bar)
F=Flanged (overlap) Z spline

and plaster frame

LENS FRAME:

FS= Flat steel frame
RA=Regressed

aluminum frame

FA=Flat aluminum frame

LENS/SHIELDING TYPE:

VA (virgin acrylic)

standard (see options and

consult factory)

LAMP QUANTITY:

2=2 Lamp
3=3 Lamp

(Not with 6" spacing)

4=4 Lamp

(T8, 2' Lamp Only)

LAMP/

FIXTURE LENGTH:

6U=6"U Lamp T8 or T12
2U=T8, 1-5/8" U Lamp
FT=Twin Tube T5
17=T8, 2' Lamp

(Nominal 24")

Other dimming options. Consult factory.

LER = FL - 58.6

IW - 56.3

BF - 0.87

Comparative yearly lighting energy cost per 1000 lumens = $4.00