Warning – Lennox Hearth X-Fires WS User Manual

Page 12

Advertising
background image

1

NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE

18.0 SPARK GAP

Figure 8 - Proper Spark Gap

1/8" to 3/16" Spark Gap

19.0 BRIEFING THE CUSTOMER

WARNING

Do not add logs or ornaments such as pine cones,

vermiculite or rock wool. Using these added items

can cause sooting.

All instructions must be left in the possession of the user for safekeeping.

If at all possible, show the customer how to light and control the appli-

ance and show the customer how to remove and replace the surround

assembly and glass door assembly.

After commissioning the appliance, the customer should be instructed

on the safe use of the appliance and the need for regular servicing.

Frequency of service depends on usage, but MUST be carried out

at least once annually. Advise that cleaning of the appliance may be

achieved when the fire is cold using a damp cloth and mild detergent

on most surfaces.

Advise that the fireplace will emit a "newness" smell for a time after

initial commissioning and that extra ventilation may be needed during

this time. Recommend that a guard be used for the protection of the

young, pets, the elderly and the infirm.

Advise the user to never place any objects on top of the appliance or

obstruction this area in any way.

A periodic visual check of the pilot flame and the burner flame should

be carried out.

The gap between the spark electrode and the pilot should be 1/8” to

3/16” to produce a good spark. There should be no need to adjust this

(DO NOT ATTEMPT TO ADJUST THE GAP). If under any circumstances

the piezo electric spark fails, the pilot cannot be lit manually.

Adjustment to the

pilot is Not allowed