1001h, Lytecaster performance recessed downlighting – Lightolier 1001H User Manual

Page 2

Advertising
background image

631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
www.lightolier.com © 2011 Philips Group • D0211

Lytecaster Performance Recessed Downlighting

1001H

Page 2 of 2

5" Aperture Horizontal Open, Performance Series, Reflector Trim

Job Information

Type:

70W ED-17 COATED LAMP HID, LUMEN RATING = 5700 LMS, CL FINISH TRIM

60˚

30˚

Coefficients Of Utilization

Ceiling

80%

70%

50%

30%

0

Wall

70 50 30 10 50 10 50 10 50 10

0

RCR

Zonal Cavity Method - Effective Floor Reflectance = 20%

Room Cavity Ratio

0 58 58 58 58 57 57 55 55 52 52 49
1 55 53 52 50 52 50 50 48 48 47 44
2 51 48 46 43 47 43 46 42 44 41 39
3 48 44 40 38 43 38 41 37 40 36 35
4 44 39 36 33 39 33 38 33 37 32 31
5 41 36 32 29 35 29 34 29 33 29 28
6 38 33 29 26 32 26 31 26 31 26 25
7 36 30 26 24 30 23 29 23 28 23 22
8 33 28 24 21 27 21 27 21 26 21 20
9 31 25 22 19 25 19 25 19 24 19 18

10 29 24 20 18 23 18 23 18 22 18 17

Determined In Accordance With Current IES Published Procedures

Luminaire Input Watts = 33.0

Candlepower Distribution

0

45

90

0

1494

1494

1494

5

1496

1509

1526

10

1426

1495

1565

15

1335

1452

1545

20

1255

1406

1512

25

1184

1346

1446

30

1032

1156

1287

35

1826

1587

1577

40

800

835

843

45

714

747

772

50

608

681

739

55

460

557

603

60

78

84

97

65

15

13

15

70

13

3

9

75

12

5

9

80

6

6

0

85

0

0

0

90

4

3

0

Trim/Frame:

1001HCL HID

Lamp lumens:

5700 lm

Input Watts:

81W

Efficiency:

49.0 %

Spacing Criterion (0-180):

1.08

Spacing Criterion (90-270):

1.24

Multiple Unit Data - RCR 2

Spacing

Avg.Initial

Watts/

On Ctr.

Footcandles

Sq. Ft.

6'

69

2.01

8'

48

1.40

10'

30

0.90

38'x38'x10' Room, Workplane 2 1/2'

above floor, 80/50/20% Reflectances

Zonal Lumens And Percentages

Zone

Lumens

%Luminaire

0-30

1157

41.0%

0-40

1766

63.0%

0-60

2763

99.0%

0-90

2800

100.0%

26W TRIPLE TUBE LAMP, LUMEN RATING = 1710 LMS, ELECTRONIC BALLAST, CL FINISH TRIM

1

2

150

300

450

600

60˚

30˚

COEFFICIENTS OF UTILIZATION

Ceiling

80%

70%

50%

30%

Wall

70 50 30 10 50 10 50 10 50 10

0

RCR

Zonal Cavity Method - Effective Floor Reflectance = 20%

Room Cavity Ratio

0 69 69 69 69 68 68 65 65 62 62 58
1 65 63 61 60 62 59 60 57 57 55 53
2 61 57 54 52 56 51 54 50 52 49 47
3 56 52 48 45 51 44 49 44 48 43 41
4 52 47 42 39 46 39 45 39 43 38 37
5 49 42 38 35 42 35 41 34 40 34 32
6 45 39 34 31 38 31 37 31 36 30 29
7 42 35 31 28 35 28 34 30 27 33 26
8 39 33 28 25 32 28 25 31 28 25 24

36 37 30 26 23 30 26 23 29 25 23 22
10 35 28 24 21 28 21 27 23 21 26 20

Determined In Accordance With Current IES Published Procedures

Luminaire Input Watts = 26

ZONAL LUMENS AND PERCENTAGES

Zone

Lumens %Lamp

%Fixt

0-30

409.25

23.9

41

0-40

614.89

36

61.7

0-60

989.42

57.9

99.2

0-90

997.25

58.3

100

90-120

0

0

0

90-130

0

0

0

90-150

0

0

0

90-180

0

0

0

0-180

997.25

58.3

100

** Efficiency = 58.3% **

ZONAL LUMEN SUMMARY

Zone

Lumens

0-10

51.35

10-20

148.05

20-30

209.85

30-40

205.64

40-50

204.86

50-60

169.66

60-70

.7

70-80

.8

80-90

.03

90-100

0

100-110

0

110-120

0

120-130

0

130-140

0

140-150

0

150-160

0

160-170

0

170-180

0

SC = 1.1

1 = 90˚

2 = 0˚

CERTIFIED TEST REPORT NO. 3181FR
COMPUTED BY LSI PROGRAM
**TEST-LITE**

CANDLEPOWER SUMMARY

Angle

0˚ CP

90˚ CP

0

538

538

5

518

561

10

506

564

15

479

561

20

454

535

25

434

494

30

380

431

35

314

347

40

279

273

45

271

255

50

259

261

55

217

231

60

25

42

65

3

4

70

1

2

75

1

1

80

0

0

85

0

0

90

0

0

500

1000

1500

0

500

1000

1500

Single Unit Data

Height to

Initial

Beam

Lighted Plane

Footcandles

Diameter

6'

42

6'

8'

23

8'

10'

15

11'

12'

10