Installation
1 3
Travis Industries
4 0 7 0 2 0 7
9 3 5 0 8 0 5 1
Installation into a Factory Built (Metal) Fireplace
The smoke shelf, shields,
damper, and baffles may
be removed if attached
with mechanical
fasteners.
“L” Vent Flex Section
6” Min.
13” Min.
HINT:
Paint the interior of the
fireplace with latex paint to
prevent fireplace odors from
entering the home.
“L” Vent
Storm Collar
Vertical Cap
Cover Plate (non-combustible)
Silicone
Seal the cover
plate with silicone.
The metal sides, frame members, or other
structural components of the factory built
fireplace may not be removed or altered.
3/8” Gap is required between
the surround panels and the
front of the fireplace.
The log shelf,
screen, and doors
(if present) must
be removed.
Use the telescoping legs to
support the insert on raised
fireplaces.
The metal floor of the firebox may
be removed leaving the fireplace
floor outer wrap.
The firebrick (refractory)
may be removed.