1101hcb, Lytecaster, Performance recessed cfl downlighting – Lightolier 1101HCB User Manual

Page 2

Advertising
background image

631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
www.lightolier.com © 2009 Philips Group • A0409

Lytecaster

®

Performance Recessed CFL Downlighting

1101HCB

Page 2 of 2

6 ¾" Aperture Horizontal Cross Blade, CFL, Performance Series, Reflector Trim

Job Information

Type:

32W TRIPLE TUBE LAMP, LUMEN RATING = 2200 LMS, ELECTRONIC BALLAST, WHITE CROSS BLADE

42W TRIPLE TUBE LAMP, LUMEN RATING = 3200 LMS, ELECTRONIC BALLAST, WHITE CROSS BLADE

60°

30°

1

2

225

450

695

900

2

1

167

333

500

666

60˚

30˚

ZONAL LUMENS AND PERCENTAGES

Zone

Lumens %Lamp

%Fixt

0-30 390.66

17.8

47.9

0-40 550.53

25

67.5

0-60 726.61

33

89.1

0-90 815.38

37.1

100

90-120 0

0

0

90-130 0

0

0

90-150

0

0

90-180 815.38

37.1

100

** Efficiency = 37.1% **

COEFFICIENTS OF UTILIZATION

Ceiling

80%

70%

50%

30%

Wall

70 50 30 10 50 10 50 10 50 10

0

RCR

Zonal Cavity Method - Effective Floor Reflectance = 20%

Room

Cavity

Ratio

0 44 44 44 44 43 43 41 41 39 39 37
1 41 40 38 37 39 37 37 36 36 34 33
2 38 36 34 32 35 32 34 31 33 30 29
3 36 32 30 28 35 32 28 31 27 30 26
4 33 30 27 25 29 25 28 24 27 26 23
5 31 27 24 22 27 22 26 22 25 22 21
6 29 25 22 20 25 20 24 20 23 20 19
7 27 23 20 18 23 18 22 18 22 18 17
8 26 21 19 17 21 17 21 17 20 17 16

36 24 20 17 16 20 16 19 16 19 15 15
10 23 19 16 15 19 14 18 14 18 14 14

Determined In Accordance With Current IES Published Procedures

Luminaire Input Watts = 35

ZONAL LUMEN SUMMARY

Zone

Lumens

0-10

59.95

10-20

147.91

20-30

183.79

30-40

159.87

40-50

103.2

50-60

72.98

60-70

50.18

70-80

28.8

80-90

9.7

90-100

0

100-110

0

110-120

0

120-130

0

130-140

0

140-150

0

150-160

0

160-170

0

170-180

0

CANDLEPOWER SUMMARY

Angle

0˚ CP

90˚ CP

0

666

666

5

635

637

10

572

597

15

494

582

20

432

528

25

383

468

30

324

401

35

263

287

40

193

177

45

142

116

50

106

97

55

80

80

60

64

64

65

51

51

70

39

39

75

27

28

80

17

18

85

8

9

90

5

5

ZONAL LUMENS AND PERCENTAGES

Zone

Lumens %Lamp

%Fixt

0-30

498.04

15.6

47.7

0-40

701.05

21.9

67.2

0-60

929.8

29.1

89.1

0-90 1043.73

32.6

100

90-120

0

0

0

90-130

0

0

0

90-150

0

0

0

90-180 1043.73

32.6

100

** Efficiency = 32.6% **

COEFFICIENTS OF UTILIZATION

Ceiling

80%

70%

50%

30%

Wall

70 50 30 10 50 10 50 10 50 10

0

RCR

Zonal Cavity Method - Effective Floor Reflectance = 20%

Room

Cavity

Ratio

0 39 39 39 39 38 38 36 36 35 35 33
1 36 35 34 33 34 32 33 31 32 30 29
2 34 31 30 28 31 28 30 27 29 27 25
3 31 29 26 25 28 24 27 24 26 24 23
4 29 26 24 22 26 22 25 21 24 21 20
5 27 24 21 20 23 19 21 19 20 19 18
6 26 22 19 18 22 18 21 17 21 17 17
7 24 20 18 16 20 16 20 16 19 16 15
8 23 19 16 15 19 15 18 15 18 15 14

36 21 18 15 14

17 14

17 14

17 14

13

10 20 16 14 13 16 13 16 13 16 13

12

Determined In Accordance With Current IES Published Procedures

Luminaire Input Watts = 47

ZONAL LUMEN SUMMARY

Zone

Lumens

0-10

73.64

10-20

188.16

20-30

236.24

30-40

203

40-50

134.48

50-60

94.28

60-70

64.6

70-80

36.97

80-90

12.35

90-100

0

100-110

0

110-120

0

120-130

0

130-140

0

140-150

0

150-160

0

160-170

0

170-180

0

CANDLEPOWER SUMMARY

Angle

0˚ CP

90˚ CP

0

816

816

5

778

801

10

701

774

15

604

751

20

526

688

25

466

599

30

394

503

35

325

369

40

249

232

45

185

154

50

136

124

55

104

102

60

82

82

65

65

65

70

50

49

75

35

35

80

22

22

85

11

11

90

2

4

SC = 0.8 x 0.98

1 – 0°

2 – 90°

CERTIFIED TEST REPORT NO. 3353FR
COMPUTED BY LSI PROGRAM
**TEST-LITE**

SC = 0.8 x 1.0

1 – 0°

2 – 90°

CERTIFIED TEST REPORT NO. 3356FR
COMPUTED BY LSI PROGRAM
**TEST-LITE**

Advertising