Cut capacity data electrode life test data, Performance quality and reliability – Lincoln Electric PCT 80 User Manual

Page 2

Advertising
background image

Pro-Cut 80

www.lincolnelectric.com

FEATURES

• One control dial with current indicators for easy operation and

setup.

• Air pressure regulator, air filter and pressure gauge are standard.

Pressure gauge is right on the control panel for easy setup.

CUT CAPACITY DATA

ELECTRODE LIFE TEST DATA

(2)

0

0.50

0.375

0.625

M t l Thi k

(I

h

)

0.75

1.0

1.25

10

20

30

40

0

0

60

120

180

20

40

60

Electrode Pit Depth (X.001 Inch)

Time in Hours

Time in Hours

0.5

1.0

CUTTING CAPACITY

Ordering Information

Description

KP2063-1B1

Electrode

KP2062-2B1

VORTECH™ Nozzle (.043)(1)

KP2062-3B1

VORTECH™ Nozzle (.053)

KP2062-5B1

VORTECH™ Nozzle (.082) Gouging

KP2064-1

Shield Cup

KP2065-1

Drag Cup

EXPENDABLE PARTS

(1) .043 Nozzle can be used when cutting at 60 amps or lower for a

smaller kerf.

A CLOSER LOOK

PERFORMANCE

QUALITY AND RELIABILITY

• Parts-In-Place safety indicator and lockout circuit to protect both

the operator and the system.

• Thermostatically protected against overheating.

• Line voltage compensation.

• Manufactured under a quality system certified to ISO 9001

requirements.

• Three-year warranty on parts and labor. (1 year warranty on

plasma torch.)

Number of Starts (20 Sec. Arc/Start)

(2) Electrode erosion of .060” is typically end of

electrode life.

Metal Thickness (inches)

Time in Hours

IPM (80% Max. Speed)

Electr

ode Pit Depth (X.001 inch)

[2]

Production

Recommended

Maximum

Capacity

Capacity

Capacity

3/4" @ 18 IPM

1" @ 11 IPM

1-1/4" @ 7 IPM