MAIN GENERATOR FRAME REMOVAL AND REPLACEMENT PROCEDURE
(CONTINUED)
TROUBLESHOOTING & REPAIR
F-53
F-53
PIPELINER® 200
FIGURE F.19 – SELECTOR SWITCH LEAD REMOVAL
SELECTOR
SWITCH
TERMINAL
LEAD (5)
A
C
B
D
E
9. Using the 1/2” wrench, remove the five heavy
flex leads from the selector switch terminals.
Label the leads for reassembly. See Figure
F.19.
FIGURE F.20 – OUTPUT TERMINAL LEAD REMOVAL
POSITIVE OUTPUT
TERMINAL AND LEAD
A
C
B
D
E
10. Using the 3/4” wrench, remove the copper
strap from the negative output terminal. See
Figure F.20.
11. Using the 3/4” wrench, remove the heavy
lead from the positive output terminal. See
Figure F. 20.