Lennox International Inc. G23 User Manual

Page 4

Advertising
background image

Page 4

Gas Valve Operation (Figure 3)
1- STOP! Read the safety information at the beginning

of this section.

2- Set thermostat to lowest setting. See figure 2.

THERMOSTATS

FIGURE 2

3- Turn off all electrical power to appliance.
4- This appliance is equipped with an ignition device

which automatically lights the burners. Do not try to

light the burners by hand.

5- Remove upper access panel.
6- On Honeywell VR8204 gas valves, turn knob on gas

valve clockwise

to OFF. For White Rodgers 36E

gas valves, move switch to OFF. Do not force the
switch. See figure 3.

GAS VALVE SHOWN IN OFF POSITION

FIGURE 3

ON

OFF

HONEYWELL VR8204 SERIES GAS VALVE

WHITE RODGERS

36E GAS VALVE

GAS VALVE

SHOWN

IN OFF

POSITION

7- Wait fifteen (15) minutes to clear out any gas. If you

then smell gas, STOP! Immediately call your gas

supplier from a neighbor's phone. Follow the gas

supplier's instructions. If you do not smell gas go to

next step.

8- For Honeywell VR8204 gas valves, turn knob on gas

valve counterclockwise

to ON. For White RodgĆ

ers 36E gas valves, move switch to ON. Do not force.

9- Replace upper access panel.
10- Turn on all electrical power to unit.
11- Set thermostat to desired setting.

NOTE-When unit is first started, steps 1 through 11 may
need to be repeated to purge air from line.

12- If the appliance still will not operate, follow the inĆ

structions To Turn Off Gas To Unit" and call your serĆ

vice technician or gas supplier.

Turning Off The Gas To The Unit
1- Set thermostat to lowest setting.
2- Turn off all electrical power to unit if service is to be

performed.

3- Remove upper access panel.
4- On Honeywell VR8204 gas valves, turn knob on gas

valve clockwise

to OFF. For White Rodgers 36E

gas valves, move switch to OFF. Do not force.

5- Replace upper access panel.

Filters

A filter must be in place anytime the unit is in operation. The
filter may be located in the unit (optional kit) or installed in a
return air grille. Ask your dealer to show you the filter location.
The filter should be inspected monthly and cleaned when
necessary to assure proper furnace operation.
Filters used inside the G23 series unit are available from LenĆ
nox and must be ordered separately. These foam filters may
be cleaned for reuse. If replacement is necessary, order LenĆ
nox part no. 31J81 for 14 X 25 inch filter for G23Q2-50,
Q3-50 and Q2/3-75 units, P-8-7822 for 16 X 25 inch filter for
G23Q3-100 units, and P-8-7831 for 20 X 25 inch filter for
G23Q3/4-100, Q3/4-125, Q4/5-75, Q4/5-100, Q5/6-125 and
Q5/6-150 units. Use the following procedure to clean filter.
Refer to figure 1.
In-Unit Filter with Bottom Return Air

1- Turn off electric power to furnace.
2- Remove blower access panel.
3- Remove filter by pressing side filter clips and pulling filter

up and out. See figure 4.

FIGURE 4

BOTTOM RETURN FILTER INSTALLATION

FURNACE

BASE BOTĆ

TOM

REAR FILTER CLIP

RETURN AIR OPENING

SIDE FILTER CLIPS (2)

FURNACE

FRONT

FURNACE

BACK

4- Clean filter with cold water and a mild soap. Direct

water through filter in the opposite direction of air

flow. Remove all soap residue.

5- Allow filter to dry then spray with filter handicoater

(P-8-5069), available from your Lennox dealer, prior

to reinstallation.