TABLE 1

Furnace

Filter Size

Furnace

Cabinet Size

Side Return

Bottom Return

17-1/2"

16 X 25 X 1 (1)

16 X 25 X 1 (1)

21"

16 X 25 X 1 (1)

20 X 25 X 1 (1)

24-1/2"

16 X 25 X 1 (2)

24 X 25 X 1 (1)

Maintenance

A qualified service technician should inspect the complete
system each season (heating and cooling). The following
maintenance procedures should only be conducted by a
qualified service technician. Do not attempt to service
the unit in any way.

WARNING

ELECTRICAL SHOCK, FIRE,

OR EXPLOSION HAZARD.

Failure to follow safety warnings exactly could result

in dangerous operation, serious injury, death or

property damage.

Improper servicing could result in dangerous operaĆ

tion, serious injury, death, or property damage.

Before servicing, disconnect all electrical power to

furnace.

When servicing controls, label all wires prior to disĆ

connecting. Take care to reconnect wires correctly.

Verify proper operation after servicing.

Venting System

WARNING

Asphyxiation Hazard
The exhaust vent for this furnace must be securely

connected to the furnace flue collar at all times.
For your safety and to fulfill the terms of the limited

warranty, a qualified service technician must annualĆ

ly inspect this furnace and its vent system.

Annually (before heating season) inspect furnace venting
system, vent cap, heat exchanger, and burners for corroĆ
sion, deterioration, or deposits of debris. Remove any obĆ
structions.

Inspect the furnace for obvious signs of deterioration.
Inspect the furnace venting system to make sure it is in
place, physically sound, and without holes, corrosion, or
blockage.
Vent pipe must be clear and free of obstructions and must
slope upward away from the furnace.
Inspect the furnace return air duct connection to ensure
duct is sealed to the furnace and terminates outside the
space containing the furnace.
Inspect the physical support of the furnace to guarantee
that it is sound without sagging, cracks or gaps around
base and it maintains seal between base and support.
Inspect and clean the condensate trap and drain.
During a seasonal check the service technician will inspect
the indoor blower, burner flames and electrical connections
along with the venting system.
Blower
Check the blower wheel for debris and clean if necessary.

The blower motors are prelubricated for extended bearing

life. No further lubrication is needed.

WARNING

The blower access panel must be securely in place

when the blower and burners are operating. Gas

fumes, which could contain carbon monoxide, can

be drawn into living space resulting in personal injuĆ

ry or death.

Burner Flame

CAUTION

To ensure proper operation, a qualified technician

should annually check the burner flame.

Electrical

1 - Check all wiring for loose connections.
2 - Check for the correct voltage at the furnace (furnace

operating).

3 - Check amp-draw on the blower motor.

Motor Nameplate__________Actual__________